Started by user Neels Hofmeyr
Building remotely on osmo-gsm-tester-rnd (osmo-gsm-tester) in workspace /home/jenkins/workspace/osmo-gsm-tester_manual-run-all
> git rev-parse --is-inside-work-tree # timeout=10
Fetching changes from the remote Git repository
> git config remote.origin.url git://git.osmocom.org/osmo-gsm-tester # timeout=10
Cleaning workspace
> git rev-parse --verify HEAD # timeout=10
Resetting working tree
> git reset --hard # timeout=10
> git clean -fdx # timeout=10
Fetching upstream changes from git://git.osmocom.org/osmo-gsm-tester
> git --version # timeout=10
> git -c core.askpass=true fetch --tags --progress git://git.osmocom.org/osmo-gsm-tester +refs/heads/*:refs/remotes/origin/*
> git rev-parse refs/remotes/origin/master^{commit} # timeout=10
> git rev-parse refs/remotes/origin/refs/heads/master^{commit} # timeout=10
Checking out Revision 36e0404f456b32898d174b8bdfb363dbe580db2e (refs/remotes/origin/master)
> git config core.sparsecheckout # timeout=10
> git checkout -f 36e0404f456b32898d174b8bdfb363dbe580db2e
> git rev-list 36e0404f456b32898d174b8bdfb363dbe580db2e # timeout=10
Copied 24 artifacts from "osmo-gsm-tester_manual-build-all" build number 35
[osmo-gsm-tester_manual-run-all] $ /bin/sh /tmp/hudson8565214351260989198.sh
+ export OSMO_GSM_TESTER_CONF=/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/example
+ export ch_resources=0
+ [ x0 = x1 ]
+ export prod=0
+ [ x0 = x1 ]
+ echo H---
H---
+ ulimit -a -H
time(seconds) unlimited
file(blocks) unlimited
data(kbytes) unlimited
stack(kbytes) unlimited
coredump(blocks) unlimited
memory(kbytes) unlimited
locked memory(kbytes) 64
process 7802
nofiles 1048576
vmemory(kbytes) unlimited
locks unlimited
rtprio 99
+ echo S---
S---
+ ulimit -a -S
time(seconds) unlimited
file(blocks) unlimited
data(kbytes) unlimited
stack(kbytes) 8192
coredump(blocks) unlimited
memory(kbytes) unlimited
locked memory(kbytes) 64
process 7802
nofiles 1048576
vmemory(kbytes) unlimited
locks unlimited
rtprio 99
+ PATH=/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src:/usr/local/bin:/usr/bin:/bin:/usr/games ./osmo-gsm-tester/contrib/jenkins-run.sh
+ base=/home/jenkins/workspace/osmo-gsm-tester_manual-run-all
+ trial_dir_prefix=trial-
+ rm -rf trial-80 trial-80-bin.tgz trial-80-run.tgz
+ trial_dir=trial-81
+ mkdir -p trial-81
+ mv osmo-bsc.build-35.tgz osmo-bts-sysmo.build-35.tgz osmo-bts-trx.build-35.tgz osmo-ggsn.build-35.tgz osmo-hlr.build-35.tgz osmo-mgw.build-35.tgz osmo-msc.build-35.tgz osmo-nitb.build-35.tgz osmo-pcu.build-35.tgz osmo-sgsn.build-35.tgz osmo-stp.build-35.tgz osmo-trx.build-35.tgz trial-81
+ cat osmo-bsc.build-35.md5 osmo-bts-sysmo.build-35.md5 osmo-bts-trx.build-35.md5 osmo-ggsn.build-35.md5 osmo-hlr.build-35.md5 osmo-mgw.build-35.md5 osmo-msc.build-35.md5 osmo-nitb.build-35.md5 osmo-pcu.build-35.md5 osmo-sgsn.build-35.md5 osmo-stp.build-35.md5 osmo-trx.build-35.md5
+ rm osmo-bsc.build-35.md5 osmo-bts-sysmo.build-35.md5 osmo-bts-trx.build-35.md5 osmo-ggsn.build-35.md5 osmo-hlr.build-35.md5 osmo-mgw.build-35.md5 osmo-msc.build-35.md5 osmo-nitb.build-35.md5 osmo-pcu.build-35.md5 osmo-sgsn.build-35.md5 osmo-stp.build-35.md5 osmo-trx.build-35.md5
+ exit_code=1
+ which osmo-gsm-tester.py
+ python3 -u /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo-gsm-tester.py trial-81 -s sms:trx-sysmocell5000 -t mo_mt_sms.py -T
combinations: ['sms:trx-sysmocell5000']
series: None
trial: 'trial-81'
tests: ['mo_mt_sms.py']
['mo_mt_sms.py']
--------------------------------------------------------------------------------------------
trial-81
--------------------------------------------------------------------------------------------
21:25:49.401975 tst trial-81: Detailed log at /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/trial-81/run.2017-09-07_21-25-49/log
---------------------------------------------------------------------
trial-81 sms:trx-sysmocell5000
---------------------------------------------------------------------
21:25:49.848365 tst sms:trx-sysmocell5000: reserving resources in /var/tmp/osmo-gsm-tester/state ...
21:25:49.877359 tst sms:trx-sysmocell5000: Reserving 1 x bts (candidates: 3)
21:25:49.903107 tst sms:trx-sysmocell5000: Reserving 1 x ip_address (candidates: 5)
21:25:49.919456 tst sms:trx-sysmocell5000: Reserving 2 x modem (candidates: 4)
----------------------------------------------
trial-81 sms:trx-sysmocell5000 mo_mt_sms.py
----------------------------------------------
21:25:50.070117 tst sms:trx-sysmocell5000: Using 1 x ip_address (candidates: 1)
21:25:50.169465 tst sms:trx-sysmocell5000: Using 1 x bts (candidates: 1)
21:25:50.295347 tst sms:trx-sysmocell5000: Using 1 x modem (candidates: 2)
21:25:50.439967 tst sms:trx-sysmocell5000: Using 1 x modem (candidates: 2)
21:25:50.562022 tst mo_mt_sms.py:9: start nitb and bts...
21:25:50.701398 run osmo-nitb_10.42.42.2: Starting osmo-nitb
21:25:52.483375 run pcap-recorder_eth1:0(filters='host 10.42.42.2 and port not 22'): Recording pcap /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/trial-81/run.2017-09-07_21-25-49/sms:trx-sysmocell5000/mo_mt_sms.py/osmo-nitb_10.42.42.2/pcap host 10.42.42.2 and port not 22
21:25:52.570234 run pcap-recorder_eth1:0(filters='host 10.42.42.2 and port not 22')(pid=11571): Launched
21:25:52.674255 run osmo-nitb_10.42.42.2(pid=11572): Launched
21:25:52.694164 run osmo-bts-trx: Starting to connect to osmo-nitb_10.42.42.2
21:25:53.512917 run osmo-bts-trx(pid=11573): Launched
21:25:53.549080 run osmo-nitb_10.42.42.2: Add subscriber {imsi='901700000009031', msisdn='27018'}
21:25:53.745037 run osmo-nitb_10.42.42.2: Add subscriber {imsi='901700000009029', msisdn='27019'}
21:25:53.963117 bus /sierra_1: Setting Powered True
21:25:54.178837 bus /sierra_1: Setting Online True
21:25:56.769049 tst /sierra_1: Connect to ('901', '70')
21:25:56.851193 bus /sierra_2: Setting Powered True
21:25:57.372752 bus /sierra_2: Setting Online True
21:26:00.269458 tst /sierra_2: Connect to ('901', '70')
21:26:00.314710 tst /sierra_1: Manufacturer: 'Sierra Wireless, Incorporated', Model: 'MC7304', Revision: 'SWI9X15C_06.03.32.04 r28324 CNSHZ-AR-BUILD 2015/05/25 01:09:15'
21:26:00.338448 tst /sierra_2: Manufacturer: 'Sierra Wireless, Incorporated', Model: 'MC7304', Revision: 'SWI9X15C_06.03.32.04 r28324 CNSHZ-AR-BUILD 2015/05/25 01:09:15'
21:26:00.356864 tst mo_mt_sms.py:23: waiting for modems to attach...
21:26:31.657609 tst mo_mt_sms.py:24: ERR: Error: Failed to find Network Operator {attempts=4, mcc_mnc=('901', '70')} [trial-81↪sms:trx-sysmocell5000↪mo_mt_sms.py:24]
21:26:31.666055 tst mo_mt_sms.py:24: TRACEBACK: Traceback (most recent call last):
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/suite.py", line 105, in run
self.path)
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/util.py", line 278, in run_python_file
spec.loader.exec_module( importlib.util.module_from_spec(spec) )
File "<frozen importlib._bootstrap_external>", line 673, in exec_module
File "<frozen importlib._bootstrap>", line 222, in _call_with_frames_removed
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/suites/sms/mo_mt_sms.py", line 24, in <module>
wait(ms_mo.is_connected, nitb.mcc_mnc())
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/test.py", line 47, in <lambda>
wait = lambda *args, **kwargs: event_module.wait(suite_run, *args, **kwargs)
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py", line 59, in wait
if not wait_no_raise(log_obj, condition, condition_args, condition_kwargs, timeout, timestep):
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py", line 50, in wait_no_raise
poll()
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py", line 39, in poll
func()
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/ofono_client.py", line 79, in poll_glib
DeferredHandling.handle_queue()
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/ofono_client.py", line 61, in handle_queue
handler(*args, **kwargs)
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/ofono_client.py", line 495, in scan_cb_register
self.schedule_scan_register(mcc_mnc)
File "/home/jenkins/workspace/osmo-gsm-tester_manual-run-all/osmo-gsm-tester/src/osmo_gsm_tester/ofono_client.py", line 438, in schedule_scan_register
raise log.Error('Failed to find Network Operator', mcc_mnc=mcc_mnc, attempts=self.register_attempts)
osmo_gsm_tester.log.Error: Failed to find Network Operator {attempts=4, mcc_mnc=('901', '70')}
[trial-81↪sms:trx-sysmocell5000↪mo_mt_sms.py:24]
21:26:31.673520 tst mo_mt_sms.py:24: Test FAILED (41.6 sec)
21:26:31.681984 run pcap-recorder_eth1:0(filters='host 10.42.42.2 and port not 22')(pid=11571): Terminating (SIGINT)
21:26:31.862328 run pcap-recorder_eth1:0(filters='host 10.42.42.2 and port not 22')(pid=11571): Terminated: ok {rc=0}
21:26:31.867470 run osmo-nitb_10.42.42.2(pid=11572): Terminating (SIGINT)
21:26:35.285203 run osmo-nitb_10.42.42.2(pid=11572): Terminated: ok {rc=0}
21:26:35.290319 run osmo-bts-trx(pid=11573): Terminating (SIGINT)
21:26:37.985283 run osmo-bts-trx(pid=11573): Terminated {rc=42}
21:26:38.004550 bus /sierra_2: Setting Powered False
21:26:38.651216 bus /sierra_2: Setting Powered False
21:26:38.670172 bus /sierra_1: Setting Powered False
---------------------------------------------------------------------
trial-81 sms:trx-sysmocell5000 FAIL
---------------------------------------------------------------------
21:26:39.736520 tst trial-81: Storing JUnit report in /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/trial-81/run.2017-09-07_21-25-49/trial-81.xml
--------------------------------------------------------------------------------------------
trial-81 FAIL
--------------------------------------------------------------------------------------------
21:26:39.756300 tst trial-81: trial-81: FAIL, 1 suites failed
FAIL: sms:trx-sysmocell5000 (fail: 1)
FAIL: mo_mt_sms.py (41.6 sec) Error: Failed to find Network Operator {attempts=4, mcc_mnc=('901', '70')}
+ rm -rf trial-81/inst
+ cd trial-81
+ readlink last_run
+ tar czf /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/trial-81-run.tgz run.2017-09-07_21-25-49
tar: run.2017-09-07_21-25-49/sms\:trx-sysmocell50: socket ignored
+ tar czf /home/jenkins/workspace/osmo-gsm-tester_manual-run-all/trial-81-bin.tgz checksums.md5 osmo-bsc.build-35.tgz osmo-bts-sysmo.build-35.tgz osmo-bts-trx.build-35.tgz osmo-ggsn.build-35.tgz osmo-hlr.build-35.tgz osmo-mgw.build-35.tgz osmo-msc.build-35.tgz osmo-nitb.build-35.tgz osmo-pcu.build-35.tgz osmo-sgsn.build-35.tgz osmo-stp.build-35.tgz osmo-trx.build-35.tgz
+ exit 1
Build step 'Execute shell' marked build as failure
Archiving artifacts
Recording test results
Finished: FAILURE