  "_class" : "hudson.tasks.junit.TestResult",
  "testActions" : [
    
  ],
  "duration" : 878.0,
  "empty" : False,
  "failCount" : 3,
  "passCount" : 1,
  "skipCount" : 0,
  "suites" : [
    {
      "cases" : [
        {
          "testActions" : [
            
          ],
          "age" : 1,
          "className" : "sms:sysmo",
          "duration" : 368.0,
          "errorDetails" : None,
          "errorStackTrace" : "name 'log' is not defined",
          "failedSince" : 13,
          "name" : "mo_mt_sms.py",
          "properties" : {
            
          },
          "skipped" : False,
          "skippedMessage" : None,
          "status" : "FAILED",
          "stderr" : "Traceback (most recent call last):\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/suite.py\", line 98, in run\u000a    self.path)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/util.py\", line 282, in run_python_file\u000a    SourceFileLoader(module_name, path).load_module()\u000a  File \"<frozen importlib._bootstrap>\", line 539, in _check_name_wrapper\u000a  File \"<frozen importlib._bootstrap>\", line 1614, in load_module\u000a  File \"<frozen importlib._bootstrap>\", line 596, in _load_module_shim\u000a  File \"<frozen importlib._bootstrap>\", line 1220, in load\u000a  File \"<frozen importlib._bootstrap>\", line 1200, in _load_unlocked\u000a  File \"<frozen importlib._bootstrap>\", line 1129, in _exec\u000a  File \"<frozen importlib._bootstrap>\", line 1471, in exec_module\u000a  File \"<frozen importlib._bootstrap>\", line 321, in _call_with_frames_removed\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/suites/sms/mo_mt_sms.py\", line 24, in <module>\u000a    wait(nitb.subscriber_attached, ms_mo, ms_mt)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/test.py\", line 40, in <lambda>\u000a    wait = lambda *args, **kwargs: event_module.wait(suite_run, *args, **kwargs)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py\", line 59, in wait\u000a    raise log.Error('Wait timeout')\u000aNameError: name 'log' is not defined\u000a",
          "stdout" : None
        }
      ],
      "duration" : 372.0,
      "enclosingBlockNames" : [
        
      ],
      "enclosingBlocks" : [
        
      ],
      "id" : None,
      "name" : "sms_sysmo",
      "nodeId" : None,
      "properties" : {
        
      },
      "stderr" : None,
      "stdout" : None,
      "timestamp" : "2017-06-12T13:22:19"
    },
    {
      "cases" : [
        {
          "testActions" : [
            
          ],
          "age" : 1,
          "className" : "aoip_sms:sysmo",
          "duration" : 372.0,
          "errorDetails" : None,
          "errorStackTrace" : "name 'log' is not defined",
          "failedSince" : 13,
          "name" : "mo_mt_sms.py",
          "properties" : {
            
          },
          "skipped" : False,
          "skippedMessage" : None,
          "status" : "FAILED",
          "stderr" : "Traceback (most recent call last):\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/suite.py\", line 98, in run\u000a    self.path)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/util.py\", line 282, in run_python_file\u000a    SourceFileLoader(module_name, path).load_module()\u000a  File \"<frozen importlib._bootstrap>\", line 539, in _check_name_wrapper\u000a  File \"<frozen importlib._bootstrap>\", line 1614, in load_module\u000a  File \"<frozen importlib._bootstrap>\", line 596, in _load_module_shim\u000a  File \"<frozen importlib._bootstrap>\", line 1220, in load\u000a  File \"<frozen importlib._bootstrap>\", line 1200, in _load_unlocked\u000a  File \"<frozen importlib._bootstrap>\", line 1129, in _exec\u000a  File \"<frozen importlib._bootstrap>\", line 1471, in exec_module\u000a  File \"<frozen importlib._bootstrap>\", line 321, in _call_with_frames_removed\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/suites/aoip_sms/mo_mt_sms.py\", line 31, in <module>\u000a    wait(msc.subscriber_attached, ms_mo, ms_mt)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/test.py\", line 40, in <lambda>\u000a    wait = lambda *args, **kwargs: event_module.wait(suite_run, *args, **kwargs)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py\", line 59, in wait\u000a    raise log.Error('Wait timeout')\u000aNameError: name 'log' is not defined\u000a",
          "stdout" : None
        }
      ],
      "duration" : 380.0,
      "enclosingBlockNames" : [
        
      ],
      "enclosingBlocks" : [
        
      ],
      "id" : None,
      "name" : "aoip_sms_sysmo",
      "nodeId" : None,
      "properties" : {
        
      },
      "stderr" : None,
      "stdout" : None,
      "timestamp" : "2017-06-12T13:28:31"
    },
    {
      "cases" : [
        {
          "testActions" : [
            
          ],
          "age" : 1,
          "className" : "sms:trx",
          "duration" : 42.0,
          "errorDetails" : None,
          "errorStackTrace" : "Process ended prematurely",
          "failedSince" : 13,
          "name" : "mo_mt_sms.py",
          "properties" : {
            
          },
          "skipped" : False,
          "skippedMessage" : None,
          "status" : "FAILED",
          "stderr" : "Traceback (most recent call last):\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/suite.py\", line 98, in run\u000a    self.path)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/util.py\", line 282, in run_python_file\u000a    SourceFileLoader(module_name, path).load_module()\u000a  File \"<frozen importlib._bootstrap>\", line 539, in _check_name_wrapper\u000a  File \"<frozen importlib._bootstrap>\", line 1614, in load_module\u000a  File \"<frozen importlib._bootstrap>\", line 596, in _load_module_shim\u000a  File \"<frozen importlib._bootstrap>\", line 1220, in load\u000a  File \"<frozen importlib._bootstrap>\", line 1200, in _load_unlocked\u000a  File \"<frozen importlib._bootstrap>\", line 1129, in _exec\u000a  File \"<frozen importlib._bootstrap>\", line 1471, in exec_module\u000a  File \"<frozen importlib._bootstrap>\", line 321, in _call_with_frames_removed\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/suites/sms/mo_mt_sms.py\", line 27, in <module>\u000a    wait(ms_mt.sms_was_received, sms)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/test.py\", line 40, in <lambda>\u000a    wait = lambda *args, **kwargs: event_module.wait(suite_run, *args, **kwargs)\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py\", line 57, in wait\u000a    if not wait_no_raise(log_obj, condition, condition_args, condition_kwargs, timeout, timestep):\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py\", line 48, in wait_no_raise\u000a    poll()\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/event_loop.py\", line 37, in poll\u000a    func()\u000a  File \"/home/jenkins/workspace/osmo-gsm-tester_manual-run/osmo-gsm-tester/src/osmo_gsm_tester/suite.py\", line 353, in poll\u000a    raise log.Error('Process ended prematurely')\u000aosmo_gsm_tester.log.Error: Process ended prematurely\u000a",
          "stdout" : None
        }
      ],
      "duration" : 46.0,
      "enclosingBlockNames" : [
        
      ],
      "enclosingBlocks" : [
        
      ],
      "id" : None,
      "name" : "sms_trx",
      "nodeId" : None,
      "properties" : {
        
      },
      "stderr" : None,
      "stdout" : None,
      "timestamp" : "2017-06-12T13:34:51"
    },
    {
      "cases" : [
        {
          "testActions" : [
            
          ],
          "age" : 0,
          "className" : "aoip_sms:trx",
          "duration" : 68.0,
          "errorDetails" : None,
          "errorStackTrace" : None,
          "failedSince" : 0,
          "name" : "mo_mt_sms.py",
          "properties" : {
            
          },
          "skipped" : False,
          "skippedMessage" : None,
          "status" : "PASSED",
          "stderr" : None,
          "stdout" : None
        }
      ],
      "duration" : 80.0,
      "enclosingBlockNames" : [
        
      ],
      "enclosingBlocks" : [
        
      ],
      "id" : None,
      "name" : "aoip_sms_trx",
      "nodeId" : None,
      "properties" : {
        
      },
      "stderr" : None,
      "stdout" : None,
      "timestamp" : "2017-06-12T13:35:36"
    }
  ]
}