Failed
gprs:trx-lms+mod-bts0-egprs.ping.py (from gprs_trx-lms+mod-bts0-egprs)
Stacktrace
osmo-stp_10.42.42.5(pid=14220): Process ended prematurely: osmo-stp_10.42.42.5(pid=14220) [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py:22↪ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14220)]
Standard Output
---------------------------------------------- trial-2364 gprs:trx-lms+mod-bts0-egprs ping.py ---------------------------------------------- 20:54:51.705278 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:51.717285 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x bts (candidates: 1) 20:54:51.857594 tst ping.py: using LAC 23662 20:54:51.982039 tst ping.py: using RAC 202 20:54:52.106154 tst ping.py: using CellId 23662 20:54:52.236041 tst ping.py: using BVCI 23663 20:54:52.260762 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.272256 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.283413 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.294832 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.306019 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.317469 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.328841 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x ip_address (candidates: 9) 20:54:52.340075 tst gprs:trx-lms+mod-bts0-egprs: Using 1 x modem (candidates: 4) 20:54:52.630075 tst ping.py:19: start network... 20:54:52.763188 run osmo-hlr_10.42.42.2: Starting osmo-hlr 20:54:53.270716 run create_hlr_db(pid=14214): Launched 20:54:53.454649 bus /gobi_6: Setting Powered False 20:54:54.475667 run create_hlr_db(pid=14214): Terminated: ok {rc=0} 20:54:54.877387 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14216): Launched 20:54:55.176377 run osmo-hlr_10.42.42.2(pid=14217): Launched 20:54:55.290502 run osmo-stp_10.42.42.5: Starting osmo-stp 20:54:55.808785 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14219): Launched 20:54:56.107120 run osmo-stp_10.42.42.5(pid=14220): Launched 20:54:56.216215 run osmo-ggsn_10.42.42.6: Starting osmo-ggsn 20:54:56.735882 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14222): Launched 20:54:56.842564 run osmo-ggsn_10.42.42.6: Setting RPATH for osmo-ggsn 20:54:57.104618 run patchelf(pid=14223): Launched 20:54:57.279073 run osmo-stp_10.42.42.5(pid=14220): ERR: Terminated: ERROR {rc=1} [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py:22↪ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14220)] 20:54:57.406953 run osmo-stp_10.42.42.5(pid=14220): stdout: | (launched: 2022-12-09_20:54:55.959919) | Copyright (C) 2015-2020 by Harald Welte <laforge@gnumonks.org> | Contributions by Holger Freyther, Neels Hofmeyr, Pau Espin, Vadim Yanitskiy | License GPLv2+: GNU GPL Version 2 or later <http://gnu.org/licenses/gpl-2.0.html> | This is free software: you are free to change and redistribute it. | There is NO WARRANTY, to the extent permitted by law. | | Free Software lives by contribution. If you use this, please contribute! | 20:54:57.535765 run osmo-stp_10.42.42.5(pid=14220): stderr: | �[0;m�[38;5;43m20221209205456129 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Creating m3ua Server (null):2905 (osmo_ss7.c:2189) | �[0;m�[38;5;43m20221209205456130 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Created m3ua server on (null):2905 (osmo_ss7.c:2207) | �[0;m�[38;5;43m20221209205456130 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m (Re)binding m3ua Server to 10.42.42.5:2905 (osmo_ss7.c:2235) | �[0;m20221209205456130 �[1;33mDLGLOBAL�[0;m �[1;33mNOTICE�[0;m unable to bind socket: 10.42.42.5:2905: Address already in use (socket.c:822) | % Unable to bind xUA server to IP(s) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.5:4239: Address already in use (socket.c:935) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.5:4239 (socket.c:946) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.5 4239 (telnet_interface.c:99) | Error binding VTY port | : Address already in use 20:54:57.659398 run osmo-stp_10.42.42.5(pid=14220): stdout: | (launched: 2022-12-09_20:54:55.959919) | Copyright (C) 2015-2020 by Harald Welte <laforge@gnumonks.org> | Contributions by Holger Freyther, Neels Hofmeyr, Pau Espin, Vadim Yanitskiy | License GPLv2+: GNU GPL Version 2 or later <http://gnu.org/licenses/gpl-2.0.html> | This is free software: you are free to change and redistribute it. | There is NO WARRANTY, to the extent permitted by law. | | Free Software lives by contribution. If you use this, please contribute! | 20:54:57.782337 run osmo-stp_10.42.42.5(pid=14220): stderr: | �[0;m�[38;5;43m20221209205456129 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Creating m3ua Server (null):2905 (osmo_ss7.c:2189) | �[0;m�[38;5;43m20221209205456130 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Created m3ua server on (null):2905 (osmo_ss7.c:2207) | �[0;m�[38;5;43m20221209205456130 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m (Re)binding m3ua Server to 10.42.42.5:2905 (osmo_ss7.c:2235) | �[0;m20221209205456130 �[1;33mDLGLOBAL�[0;m �[1;33mNOTICE�[0;m unable to bind socket: 10.42.42.5:2905: Address already in use (socket.c:822) | % Unable to bind xUA server to IP(s) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.5:4239: Address already in use (socket.c:935) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.5:4239 (socket.c:946) | 20221209205456131 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.5 4239 (telnet_interface.c:99) | Error binding VTY port | : Address already in use 20:54:57.924659 run patchelf(pid=14223): Terminating (SIGINT) 20:54:58.092143 run patchelf(pid=14223): Terminated: ok {rc=0} 20:54:58.122623 tst ping.py:22: ERR: Error: osmo-stp_10.42.42.5(pid=14220): Process ended prematurely: osmo-stp_10.42.42.5(pid=14220) [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py:22↪ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14220)] [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py:22] 20:54:58.131394 tst ping.py:22: Test FAILED (6.4 sec) 20:54:58.191504 run osmo-hlr_10.42.42.2(pid=14217): ERR: Terminated: ERROR {rc=237} [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py↪ping.py↪osmo-hlr_10.42.42.2↪osmo-hlr_10.42.42.2(pid=14217)] 20:54:58.240300 run osmo-hlr_10.42.42.2(pid=14217): stdout: | (launched: 2022-12-09_20:54:55.029087) 20:54:58.289717 run osmo-hlr_10.42.42.2(pid=14217): stderr: | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'SECURE_DELETE' (db.c:579) | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'SOUNDEX' (db.c:579) | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'TEMP_STORE=1' (db.c:579) | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'THREADSAFE=1' (db.c:579) | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'USE_URI' (db.c:579) | �[0;m�[1;31m20221209205455204 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m Not setting SQL log callback: SQLite3 compiled without support for it (db.c:596) | �[0;m�[1;31m20221209205455217 �[1;33mDDB�[0;m�[1;31m �[1;33mNOTICE�[0;m�[1;31m Database '/home/jenkins/workspace/osmo-gsm-tester_run-prod/trial-2364/run.2022-12-09_20-04-44/gprs:trx-lms+mod-bts0-egprs/ping.py/osmo-hlr_10.42.42.2/hlr.db' has HLR DB schema version 6 (db.c:636) | �[0;m20221209205455225 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.2:4258: Address already in use (socket.c:935) | 20221209205455226 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.2:4258 (socket.c:946) | 20221209205455226 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.2 4258 (telnet_interface.c:99) 20:54:58.331277 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14216): Terminating (SIGTERM) 20:54:58.370613 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14219): Terminating (SIGTERM) 20:54:58.409959 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14222): Terminating (SIGTERM) 20:54:58.419537 --- ParallelTerminationStrategy: PID 14216 died... 20:54:58.472398 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14216): Terminated: ok {rc=0} 20:54:58.482349 --- ParallelTerminationStrategy: PID 14219 died... 20:54:58.535740 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14219): Terminated: ok {rc=0} 20:54:58.545499 --- ParallelTerminationStrategy: PID 14222 died... 20:54:58.598493 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14222): Terminated: ok {rc=0} 20:54:58.686209 bus /gobi_6: Setting Powered False
Standard Error
Traceback (most recent call last): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run self.path) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file spec.loader.exec_module( importlib.util.module_from_spec(spec) ) File "<frozen importlib._bootstrap_external>", line 728, in exec_module File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/gprs/ping.py", line 22, in <module> ggsn.start() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/ggsn_osmo.py", line 57, in start util.change_elf_rpath(binary, util.prepend_library_path(lib), self.run_dir.new_dir('patchelf')) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 57, in change_elf_rpath proc.launch_sync() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 214, in launch_sync raise e File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 211, in launch_sync self.wait() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 421, in wait MainLoop.wait(self.terminated, timeout=timeout) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise self.poll(may_block=True) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll self.deferred_handling.handle_queue() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue handler(*args, **kwargs) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll raise log_module.Error('Process ended prematurely: %s' % proc.name()) osmo_gsm_tester.core.log.Error: osmo-stp_10.42.42.5(pid=14220): Process ended prematurely: osmo-stp_10.42.42.5(pid=14220) [trial-2364↪gprs:trx-lms+mod-bts0-egprs↪ping.py:22↪ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14220)]