Failed
nitb_ussd:trx-lms-limenet-micro.assert_extension.py (from nitb_ussd_trx-lms-limenet-micro)
Stacktrace
osmo-nitb_10.42.42.2(pid=24775): Process ended prematurely: osmo-nitb_10.42.42.2(pid=24775) [trial-2365↪nitb_ussd:trx-lms-limenet-micro↪assert_extension.py:12↪assert_extension.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=24775)]
Standard Output
----------------------------------------------
trial-2365 nitb_ussd:trx-lms-limenet-micro assert_extension.py
----------------------------------------------
22:37:28.202164 tst nitb_ussd:trx-lms-limenet-micro: Using 1 x ip_address (candidates: 1)
22:37:28.212879 tst nitb_ussd:trx-lms-limenet-micro: Using 1 x bts (candidates: 1)
22:37:28.345969 tst assert_extension.py: using LAC 24139
22:37:28.470415 tst assert_extension.py: using RAC 169
22:37:28.594877 tst assert_extension.py: using CellId 24139
22:37:28.718430 tst assert_extension.py: using BVCI 24140
22:37:28.742415 tst nitb_ussd:trx-lms-limenet-micro: Using 1 x modem (candidates: 1)
22:37:29.018750 tst assert_extension.py:10: start nitb and bts...
22:37:29.142232 run osmo-nitb_10.42.42.2: Starting osmo-nitb
22:37:29.760144 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=24774): Launched
22:37:30.055078 run osmo-nitb_10.42.42.2(pid=24775): Launched
22:37:30.239261 run osmo-nitb_10.42.42.2(pid=24775): ERR: Terminated: ERROR {rc=2} [trial-2365↪nitb_ussd:trx-lms-limenet-micro↪assert_extension.py:12↪assert_extension.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=24775)]
22:37:30.374880 run osmo-nitb_10.42.42.2(pid=24775): stdout:
| (launched: 2022-12-09_22:37:29.911390)
22:37:30.510699 run osmo-nitb_10.42.42.2(pid=24775): stderr:
| (launched: 2022-12-09_22:37:29.955652)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years. If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ======================================================================
22:37:30.641920 run osmo-nitb_10.42.42.2(pid=24775): stdout:
| (launched: 2022-12-09_22:37:29.911390)
22:37:30.771680 run osmo-nitb_10.42.42.2(pid=24775): stderr:
| (launched: 2022-12-09_22:37:29.955652)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years. If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ======================================================================
22:37:31.176661 tst osmo-nitb_10.42.42.2(pid=24775): stdout:
| (launched: 2022-12-09_22:37:29.911390)
22:37:31.298751 tst osmo-nitb_10.42.42.2(pid=24775): stderr:
| (launched: 2022-12-09_22:37:29.955652)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years. If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ======================================================================
22:37:31.352392 tst assert_extension.py:12: ERR: Error: osmo-nitb_10.42.42.2(pid=24775): Process ended prematurely: osmo-nitb_10.42.42.2(pid=24775) [trial-2365↪nitb_ussd:trx-lms-limenet-micro↪assert_extension.py:12↪assert_extension.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=24775)] [trial-2365↪nitb_ussd:trx-lms-limenet-micro↪assert_extension.py:12]
22:37:31.361013 tst assert_extension.py:12: Test FAILED (3.1 sec)
22:37:31.397016 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=24774): Terminating (SIGTERM)
22:37:31.575146 --- ParallelTerminationStrategy: PID 24774 died...
22:37:31.632299 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=24774): Terminated: ok {rc=0}
22:37:31.737083 bus /sierra_2: Setting Powered False
Standard Error
Traceback (most recent call last):
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run
self.path)
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file
spec.loader.exec_module( importlib.util.module_from_spec(spec) )
File "<frozen importlib._bootstrap_external>", line 728, in exec_module
File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/nitb_ussd/assert_extension.py", line 12, in <module>
nitb.start()
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/nitb_osmo.py", line 67, in start
self.ctrl.connect()
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/osmo_ctrl.py", line 92, in connect
MainLoop.wait(self.try_connect, timestep=3, timeout=timeout)
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait
if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep):
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise
self.poll(may_block=True)
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll
self.deferred_handling.handle_queue()
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue
handler(*args, **kwargs)
File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll
raise log_module.Error('Process ended prematurely: %s' % proc.name())
osmo_gsm_tester.core.log.Error: osmo-nitb_10.42.42.2(pid=24775): Process ended prematurely: osmo-nitb_10.42.42.2(pid=24775) [trial-2365↪nitb_ussd:trx-lms-limenet-micro↪assert_extension.py:12↪assert_extension.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=24775)]