Failed
gprs:trx-sysmocell5000.ping_idle_ping.py (from gprs_trx-sysmocell5000)
Stacktrace
osmo-stp_10.42.42.5(pid=14522): Process ended prematurely: osmo-stp_10.42.42.5(pid=14522) [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py:27↪ping_idle_ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14522)]
Standard Output
---------------------------------------------- trial-2396 gprs:trx-sysmocell5000 ping_idle_ping.py ---------------------------------------------- 23:43:41.848448 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:41.859631 tst gprs:trx-sysmocell5000: Using 1 x bts (candidates: 1) 23:43:41.996312 tst ping_idle_ping.py: using LAC 37050 23:43:42.114112 tst ping_idle_ping.py: using RAC 75 23:43:42.229803 tst ping_idle_ping.py: using CellId 37050 23:43:42.345217 tst ping_idle_ping.py: using BVCI 37051 23:43:42.367532 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.378288 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.388696 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.399185 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.410360 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.421803 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.433168 tst gprs:trx-sysmocell5000: Using 1 x ip_address (candidates: 9) 23:43:42.444270 tst gprs:trx-sysmocell5000: Using 1 x modem (candidates: 4) 23:43:42.720007 tst ping_idle_ping.py:24: start network... 23:43:42.842106 run osmo-hlr_10.42.42.2: Starting osmo-hlr 23:43:43.311750 run create_hlr_db(pid=14516): Launched 23:43:43.481415 bus /gobi_6: Setting Powered False 23:43:44.514059 run create_hlr_db(pid=14516): Terminated: ok {rc=0} 23:43:44.930065 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14518): Launched 23:43:45.243495 run osmo-hlr_10.42.42.2(pid=14519): Launched 23:43:45.363794 run osmo-stp_10.42.42.5: Starting osmo-stp 23:43:45.928236 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14521): Launched 23:43:46.368424 run osmo-stp_10.42.42.5(pid=14522): Launched 23:43:46.553214 run osmo-ggsn_10.42.42.6: Starting osmo-ggsn 23:43:47.122269 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14524): Launched 23:43:47.247659 run osmo-ggsn_10.42.42.6: Setting RPATH for osmo-ggsn 23:43:47.521520 run patchelf(pid=14525): Launched 23:43:47.705764 run osmo-stp_10.42.42.5(pid=14522): ERR: Terminated: ERROR {rc=1} [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py:27↪ping_idle_ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14522)] 23:43:47.840189 run osmo-stp_10.42.42.5(pid=14522): stdout: | (launched: 2022-12-13_23:43:46.101405) | Copyright (C) 2015-2020 by Harald Welte <laforge@gnumonks.org> | Contributions by Holger Freyther, Neels Hofmeyr, Pau Espin, Vadim Yanitskiy | License GPLv2+: GNU GPL Version 2 or later <http://gnu.org/licenses/gpl-2.0.html> | This is free software: you are free to change and redistribute it. | There is NO WARRANTY, to the extent permitted by law. | | Free Software lives by contribution. If you use this, please contribute! | 23:43:47.975595 run osmo-stp_10.42.42.5(pid=14522): stderr: | �[0;m�[38;5;43m20221213234346369 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Creating m3ua Server (null):2905 (osmo_ss7.c:2189) | �[0;m�[38;5;43m20221213234346369 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Created m3ua server on (null):2905 (osmo_ss7.c:2207) | �[0;m�[38;5;43m20221213234346370 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m (Re)binding m3ua Server to 10.42.42.5:2905 (osmo_ss7.c:2235) | �[0;m20221213234346370 �[1;33mDLGLOBAL�[0;m �[1;33mNOTICE�[0;m unable to bind socket: 10.42.42.5:2905: Address already in use (socket.c:822) | % Unable to bind xUA server to IP(s) | 20221213234346370 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.5:4239: Address already in use (socket.c:935) | 20221213234346371 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.5:4239 (socket.c:946) | 20221213234346371 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.5 4239 (telnet_interface.c:99) | Error binding VTY port | : Address already in use 23:43:48.106288 run osmo-stp_10.42.42.5(pid=14522): stdout: | (launched: 2022-12-13_23:43:46.101405) | Copyright (C) 2015-2020 by Harald Welte <laforge@gnumonks.org> | Contributions by Holger Freyther, Neels Hofmeyr, Pau Espin, Vadim Yanitskiy | License GPLv2+: GNU GPL Version 2 or later <http://gnu.org/licenses/gpl-2.0.html> | This is free software: you are free to change and redistribute it. | There is NO WARRANTY, to the extent permitted by law. | | Free Software lives by contribution. If you use this, please contribute! | 23:43:48.235895 run osmo-stp_10.42.42.5(pid=14522): stderr: | �[0;m�[38;5;43m20221213234346369 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Creating m3ua Server (null):2905 (osmo_ss7.c:2189) | �[0;m�[38;5;43m20221213234346369 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m Created m3ua server on (null):2905 (osmo_ss7.c:2207) | �[0;m�[38;5;43m20221213234346370 �[1;32mDLSS7�[0;m�[38;5;43m �[1;32mINFO�[0;m�[38;5;43m (Re)binding m3ua Server to 10.42.42.5:2905 (osmo_ss7.c:2235) | �[0;m20221213234346370 �[1;33mDLGLOBAL�[0;m �[1;33mNOTICE�[0;m unable to bind socket: 10.42.42.5:2905: Address already in use (socket.c:822) | % Unable to bind xUA server to IP(s) | 20221213234346370 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.5:4239: Address already in use (socket.c:935) | 20221213234346371 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.5:4239 (socket.c:946) | 20221213234346371 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.5 4239 (telnet_interface.c:99) | Error binding VTY port | : Address already in use 23:43:48.386407 run patchelf(pid=14525): Terminating (SIGINT) 23:43:48.562475 run patchelf(pid=14525): Terminated: ok {rc=0} 23:43:48.594436 tst ping_idle_ping.py:27: ERR: Error: osmo-stp_10.42.42.5(pid=14522): Process ended prematurely: osmo-stp_10.42.42.5(pid=14522) [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py:27↪ping_idle_ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14522)] [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py:27] 23:43:48.603630 tst ping_idle_ping.py:27: Test FAILED (6.7 sec) 23:43:48.666664 run osmo-hlr_10.42.42.2(pid=14519): ERR: Terminated: ERROR {rc=237} [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py↪ping_idle_ping.py↪osmo-hlr_10.42.42.2↪osmo-hlr_10.42.42.2(pid=14519)] 23:43:48.718425 run osmo-hlr_10.42.42.2(pid=14519): stdout: | (launched: 2022-12-13_23:43:45.089479) 23:43:48.770845 run osmo-hlr_10.42.42.2(pid=14519): stderr: | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'SECURE_DELETE' (db.c:579) | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'SOUNDEX' (db.c:579) | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'TEMP_STORE=1' (db.c:579) | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'THREADSAFE=1' (db.c:579) | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m SQLite3 compiled with 'USE_URI' (db.c:579) | �[0;m�[1;31m20221213234345286 �[1;34mDDB�[0;m�[1;31m �[1;34mDEBUG�[0;m�[1;31m Not setting SQL log callback: SQLite3 compiled without support for it (db.c:596) | �[0;m�[1;31m20221213234345298 �[1;33mDDB�[0;m�[1;31m �[1;33mNOTICE�[0;m�[1;31m Database '/home/jenkins/workspace/osmo-gsm-tester_run-prod/trial-2396/run.2022-12-13_23-11-51/gprs:trx-sysmocell5000/ping_idle_ping.py/osmo-hlr_10.42.42.2/hlr.db' has HLR DB schema version 6 (db.c:636) | �[0;m20221213234345306 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m unable to bind socket:10.42.42.2:4258: Address already in use (socket.c:935) | 20221213234345306 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m no suitable addr found for: 10.42.42.2:4258 (socket.c:946) | 20221213234345306 �[1;31mDLGLOBAL�[0;m �[1;31mERROR�[0;m Cannot bind telnet at 10.42.42.2 4258 (telnet_interface.c:99) 23:43:48.815254 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14518): Terminating (SIGTERM) 23:43:48.857304 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14521): Terminating (SIGTERM) 23:43:48.899612 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14524): Terminating (SIGTERM) 23:43:48.909369 --- ParallelTerminationStrategy: PID 14518 died... 23:43:48.965540 run pcap-recorder_any(filters='host 10.42.42.2')(pid=14518): Terminated: ok {rc=0} 23:43:48.975514 --- ParallelTerminationStrategy: PID 14521 died... 23:43:49.031583 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=14521): Terminated: ok {rc=0} 23:43:49.041689 --- ParallelTerminationStrategy: PID 14524 died... 23:43:49.097547 run pcap-recorder_any(filters='host 10.42.42.6')(pid=14524): Terminated: ok {rc=0} 23:43:49.183801 bus /gobi_6: Setting Powered False
Standard Error
Traceback (most recent call last): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run self.path) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file spec.loader.exec_module( importlib.util.module_from_spec(spec) ) File "<frozen importlib._bootstrap_external>", line 728, in exec_module File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/gprs/ping_idle_ping.py", line 27, in <module> ggsn.start() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/ggsn_osmo.py", line 57, in start util.change_elf_rpath(binary, util.prepend_library_path(lib), self.run_dir.new_dir('patchelf')) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 57, in change_elf_rpath proc.launch_sync() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 214, in launch_sync raise e File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 211, in launch_sync self.wait() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/process.py", line 421, in wait MainLoop.wait(self.terminated, timeout=timeout) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise self.poll(may_block=True) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll self.deferred_handling.handle_queue() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue handler(*args, **kwargs) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll raise log_module.Error('Process ended prematurely: %s' % proc.name()) osmo_gsm_tester.core.log.Error: osmo-stp_10.42.42.5(pid=14522): Process ended prematurely: osmo-stp_10.42.42.5(pid=14522) [trial-2396↪gprs:trx-sysmocell5000↪ping_idle_ping.py:27↪ping_idle_ping.py↪osmo-stp_10.42.42.5↪osmo-stp_10.42.42.5(pid=14522)]