06:40:18.649499 mtc BTS_Tests.ttcn:8061 Starting external command `../ttcn3-tcpdump-start.sh BTS_Tests.TC_chopped_ipa_ping'. 06:40:19.655601 mtc BTS_Tests.ttcn:8061 External command `../ttcn3-tcpdump-start.sh BTS_Tests.TC_chopped_ipa_ping' was executed successfully (exit status: 0). 06:40:19.655661 mtc BTS_Tests.ttcn:8061 Test case TC_chopped_ipa_ping started. 06:40:19.655671 mtc BTS_Tests.ttcn:8061 Initializing variables, timers and ports of component type BTS_Tests.test_CT inside testcase TC_chopped_ipa_ping. 06:40:19.655743 mtc BTS_Tests.ttcn:8061 Port IPA_CTRL was started. 06:40:19.655750 mtc BTS_Tests.ttcn:8061 Port RSL_CCHAN was started. 06:40:19.655753 mtc BTS_Tests.ttcn:8061 Port L1CTL was started. 06:40:19.655757 mtc BTS_Tests.ttcn:8061 Port BTS_TRXC was started. 06:40:19.655760 mtc BTS_Tests.ttcn:8061 Port BTSVTY was started. 06:40:19.655763 mtc BTS_Tests.ttcn:8061 Port BSCVTY was started. 06:40:19.655766 mtc BTS_Tests.ttcn:8061 Port PCU was started. 06:40:19.655770 mtc BTS_Tests.ttcn:8061 Component type BTS_Tests.test_CT was initialized. 06:40:19.655814 mtc IPA_Testing.ttcn:225 Creating new PTC with component type IPA_Testing.IPA_CT. 06:40:19.658394 889 - Warning: A plug-in from the same path `libjunitlogger2' is already active, skipping plug-in 06:40:19.658471 889 - TTCN-3 Parallel Test Component started on d0476726be1f. Component reference: 889, component type: IPA_Testing.IPA_CT. Version: 9.0.0. 06:40:19.658484 889 - TTCN Logger v2.2 options: TimeStampFormat:=Time; LogEntityName:=No; LogEventTypes:=No; SourceInfoFormat:=Single; LogSensitiveData:=No; *.FileMask:=LOG_ALL | MATCHING | DEBUG; *.ConsoleMask:=ERROR | TESTCASE | USER | VERDICTOP | WARNING; LogFileSize:=0; LogFileNumber:=1; DiskFullAction:=Error 06:40:19.658510 889 - Connected to MC. 06:40:19.658518 889 - Initializing variables, timers and ports of component type IPA_Testing.IPA_CT inside testcase TC_chopped_ipa_ping. 06:40:19.658627 mtc IPA_Testing.ttcn:225 PTC was created. Component reference: 889, alive: no, type: IPA_Testing.IPA_CT. 06:40:19.658679 mtc IPA_Testing.ttcn:226 Starting function f_TC_chopped_ipa_ping("172.18.21.10", 3003, LISTEN_FOR_CLIENT (1)) on component 889. 06:40:19.658852 mtc IPA_Testing.ttcn:226 Function was started. 06:40:19.659431 889 - Port IPL4 was started. 06:40:19.659445 889 - Component type IPA_Testing.IPA_CT was initialized. 06:40:19.659507 889 - Starting function f_TC_chopped_ipa_ping("172.18.21.10", 3003, LISTEN_FOR_CLIENT (1)). 06:40:19.659622 889 IPA_Testing.ttcn:91 Mapping port 889:IPL4 to system:IPL4. 06:40:19.659740 889 IPA_Testing.ttcn:91 Port IPL4 was mapped to system:IPL4. 06:40:19.659864 889 IPA_Testing.ttcn:91 Map operation of 889:IPL4 to system:IPL4 finished. 06:40:19.659964 889 IPA_Testing.ttcn:102 entering f__IPL4__PROVIDER__listen: 172.18.21.10:3003 / TCP 06:40:19.660406 889 IPA_Testing.ttcn:102 IPL4: f_IPL4_listen result: { errorCode := omit, connId := 1, os_error_code := omit, os_error_text := omit } 06:40:19.660465 889 IPA_Testing.ttcn:115 Start timer g_Tguard: 60 s 06:40:19.660486 889 IPA_Testing.ttcn:116 Altstep as_Tguard was activated as default, id 1 06:40:20.350138 889 IPA_Testing.ttcn:147 Message enqueued on IPL4 from system @Socket_API_Definitions.PortEvent : { connOpened := { connId := 2, remName := "172.18.21.20", remPort := 43807, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 1 06:40:20.350278 889 IPA_Testing.ttcn:147 Matching on port IPL4 succeeded: matched 06:40:20.350309 889 IPA_Testing.ttcn:147 Receive operation on port IPL4 succeeded, message from system(): @Socket_API_Definitions.PortEvent : { connOpened := { connId := 2, remName := "172.18.21.20", remPort := 43807, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 1 06:40:20.350331 889 IPA_Testing.ttcn:147 Message with id 1 was extracted from the queue of IPL4. 06:40:20.350364 889 IPA_Testing.ttcn:129 sending byte '00'O 06:40:20.350571 889 IPA_Testing.ttcn:70 Sent on IPL4 to system @IPL4asp_Types.ASP_SendTo : { connId := 2, remName := "172.18.21.20", remPort := 43807, proto := { tcp := { } }, msg := '00'O } 06:40:20.350676 889 Osmocom_Types.ttcn:118 Start timer T: 6 s 06:40:20.350719 889 Osmocom_Types.ttcn:119 Message enqueued on IPL4 from system @Socket_API_Definitions.PortEvent : { connOpened := { connId := 3, remName := "172.18.21.20", remPort := 44931, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 2 06:40:20.350734 889 Osmocom_Types.ttcn:119 Message enqueued on IPL4 from system @Socket_API_Definitions.PortEvent : { connOpened := { connId := 4, remName := "172.18.21.20", remPort := 34599, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 3 06:40:20.350746 889 Osmocom_Types.ttcn:119 Message enqueued on IPL4 from system @Socket_API_Definitions.PortEvent : { connOpened := { connId := 5, remName := "172.18.21.20", remPort := 41981, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 4 06:40:26.354318 889 Osmocom_Types.ttcn:119 Timeout T: 6 s 06:40:26.354485 889 IPA_Testing.ttcn:129 sending byte '01'O 06:40:26.354543 889 IPA_Testing.ttcn:70 Sent on IPL4 to system @IPL4asp_Types.ASP_SendTo : { connId := 2, remName := "172.18.21.20", remPort := 43807, proto := { tcp := { } }, msg := '01'O } 06:40:26.354611 889 Osmocom_Types.ttcn:118 Start timer T: 6 s 06:40:32.358309 889 Osmocom_Types.ttcn:119 Timeout T: 6 s 06:40:32.358366 889 IPA_Testing.ttcn:129 sending byte 'FE'O 06:40:32.358399 889 IPA_Testing.ttcn:70 Sent on IPL4 to system @IPL4asp_Types.ASP_SendTo : { connId := 2, remName := "172.18.21.20", remPort := 43807, proto := { tcp := { } }, msg := 'FE'O } 06:40:32.358443 889 Osmocom_Types.ttcn:118 Start timer T: 6 s 06:40:38.362317 889 Osmocom_Types.ttcn:119 Timeout T: 6 s 06:40:38.362374 889 IPA_Testing.ttcn:129 sending byte '00'O 06:40:38.362406 889 IPA_Testing.ttcn:70 Sent on IPL4 to system @IPL4asp_Types.ASP_SendTo : { connId := 2, remName := "172.18.21.20", remPort := 43807, proto := { tcp := { } }, msg := '00'O } 06:40:38.362445 889 Osmocom_Types.ttcn:118 Start timer T: 6 s 06:40:38.362530 889 Osmocom_Types.ttcn:119 Warning: There is no GetMsgLen function registered for connId: 2. The messages will not be dissected on this connection! This warning is logged only once per testport. 06:40:38.362587 889 Osmocom_Types.ttcn:119 Message enqueued on IPL4 from system @IPL4asp_Types.ASP_RecvFrom : { connId := 2, remName := "172.18.21.20", remPort := 43807, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0, msg := '0001FE01'O } id 5 06:40:44.366313 889 Osmocom_Types.ttcn:119 Timeout T: 6 s 06:40:44.366548 889 IPA_Testing.ttcn:155 Matching on port IPL4 failed: Type of the first message in the queue is not @IPL4asp_Types.ASP_RecvFrom. 06:40:44.366618 889 IPA_Testing.ttcn:159 Matching on port IPL4 succeeded. 06:40:44.366636 889 IPA_Testing.ttcn:159 Receive operation on port IPL4 succeeded, message from system(): @Socket_API_Definitions.PortEvent: { connOpened := { connId := 3, remName := "172.18.21.20", remPort := 44931, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 2 06:40:44.366651 889 IPA_Testing.ttcn:159 Message with id 2 was extracted from the queue of IPL4. 06:40:44.366662 889 IPA_Testing.ttcn:155 Matching on port IPL4 failed: Type of the first message in the queue is not @IPL4asp_Types.ASP_RecvFrom. 06:40:44.366669 889 IPA_Testing.ttcn:159 Matching on port IPL4 succeeded. 06:40:44.366678 889 IPA_Testing.ttcn:159 Receive operation on port IPL4 succeeded, message from system(): @Socket_API_Definitions.PortEvent: { connOpened := { connId := 4, remName := "172.18.21.20", remPort := 34599, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 3 06:40:44.366686 889 IPA_Testing.ttcn:159 Message with id 3 was extracted from the queue of IPL4. 06:40:44.366693 889 IPA_Testing.ttcn:155 Matching on port IPL4 failed: Type of the first message in the queue is not @IPL4asp_Types.ASP_RecvFrom. 06:40:44.366700 889 IPA_Testing.ttcn:159 Matching on port IPL4 succeeded. 06:40:44.366708 889 IPA_Testing.ttcn:159 Receive operation on port IPL4 succeeded, message from system(): @Socket_API_Definitions.PortEvent: { connOpened := { connId := 5, remName := "172.18.21.20", remPort := 41981, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0 } } id 4 06:40:44.366715 889 IPA_Testing.ttcn:159 Message with id 4 was extracted from the queue of IPL4. 06:40:44.366790 889 IPA_Testing.ttcn:155 Matching on port IPL4 succeeded: matched 06:40:44.366806 889 IPA_Testing.ttcn:155 Receive operation on port IPL4 succeeded, message from system(): @IPL4asp_Types.ASP_RecvFrom : { connId := 2, remName := "172.18.21.20", remPort := 43807, locName := "172.18.21.10", locPort := 3003, proto := { tcp := { } }, userData := 0, msg := '0001FE01'O } id 5 06:40:44.366816 889 IPA_Testing.ttcn:155 Message with id 5 was extracted from the queue of IPL4. 06:40:44.366823 889 IPA_Testing.ttcn:156 received pong from "172.18.21.20" port 43807: '0001FE01'O 06:40:44.366880 889 IPA_Testing.ttcn:157 setverdict(pass): none -> pass 06:40:44.366909 889 - Function f_TC_chopped_ipa_ping finished. PTC terminates. 06:40:44.366919 889 - Terminating component type IPA_Testing.IPA_CT. 06:40:44.366936 889 - Default with id 1 (altstep as_Tguard) was deactivated. 06:40:44.366954 889 - Stop timer g_Tguard: 60 s 06:40:44.366965 889 - Removing unterminated mapping between port IPL4 and system:IPL4. 06:40:44.367349 889 - Port IPL4 was unmapped from system:IPL4. 06:40:44.367371 889 - Port IPL4 was stopped. 06:40:44.367380 889 - Component type IPA_Testing.IPA_CT was shut down inside testcase TC_chopped_ipa_ping. 06:40:44.367393 889 - Final verdict of PTC: pass 06:40:44.367445 mtc IPA_Testing.ttcn:227 PTC with component reference 889 is done. 06:40:44.367488 889 - Disconnected from MC. 06:40:44.367489 mtc BTS_Tests.ttcn:8062 Terminating component type BTS_Tests.test_CT. 06:40:44.367502 mtc BTS_Tests.ttcn:8062 Port IPA_CTRL was stopped. 06:40:44.367513 mtc BTS_Tests.ttcn:8062 Port RSL_CCHAN was stopped. 06:40:44.367520 mtc BTS_Tests.ttcn:8062 Port L1CTL was stopped. 06:40:44.367525 889 - TTCN-3 Parallel Test Component finished. 06:40:44.367527 mtc BTS_Tests.ttcn:8062 Port BTS_TRXC was stopped. 06:40:44.367533 mtc BTS_Tests.ttcn:8062 Port BTSVTY was stopped. 06:40:44.367539 mtc BTS_Tests.ttcn:8062 Port BSCVTY was stopped. 06:40:44.367546 mtc BTS_Tests.ttcn:8062 Port PCU was stopped. 06:40:44.367552 mtc BTS_Tests.ttcn:8062 Component type BTS_Tests.test_CT was shut down inside testcase TC_chopped_ipa_ping. 06:40:44.367561 mtc BTS_Tests.ttcn:8062 Waiting for PTCs to finish. 06:40:44.367643 mtc BTS_Tests.ttcn:8062 Setting final verdict of the test case. 06:40:44.367725 mtc BTS_Tests.ttcn:8062 Local verdict of MTC: none 06:40:44.367760 mtc BTS_Tests.ttcn:8062 Local verdict of PTC with component reference 889: pass (none -> pass) 06:40:44.367791 mtc BTS_Tests.ttcn:8062 Test case TC_chopped_ipa_ping finished. Verdict: pass 06:40:44.367826 mtc BTS_Tests.ttcn:8062 Starting external command `../ttcn3-tcpdump-stop.sh BTS_Tests.TC_chopped_ipa_ping pass'. 06:40:49.920156 mtc BTS_Tests.ttcn:8062 External command `../ttcn3-tcpdump-stop.sh BTS_Tests.TC_chopped_ipa_ping pass' was executed successfully (exit status: 0). 06:40:49.920232 mtc BTS_Tests.ttcn:8065 Switching to log file `BTS_Tests-TC_chopped_ipa_payload-d0476726be1f-mtc.log'