((*)) | / \ OsmoBTS 20260125095251095 DLGLOBAL NOTICE Setting SCHED_RR priority 30 (cpu_sched_vty.c:471) 20260125095251096 DLGLOBAL NOTICE Setting up GSMTAP Um forwarding '(null)'->'127.0.0.1:4729' (main.c:363) 20260125095251096 DLCTRL NOTICE CTRL at 127.0.0.1 4238 (control_if.c:1026) 20260125095251096 DLGLOBAL NOTICE Available via telnet 127.0.0.1 4241 (telnet_interface.c:88) 20260125095251096 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.11) in progress... (abis.c:170) 20260125095251096 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.11:3002 (ipaccess.c:1079) 20260125095251097 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095251097 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095251098 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095251098 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095251098 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:444) 20260125095251098 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095256099 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095256099 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095256105 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095256107 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown O&M msg_disc 0x40 (oml.c:96)  (oml.c:100) 20260125095256123 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:45807){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095256123 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095256123 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095256123 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095256124 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095256124 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095256124 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095256124 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095256124 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095256124 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095256124 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095256124 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095256124 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095301125 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095301125 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095301132 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095301133 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095301134 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095301135 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095301136 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095301138 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown Formatted O&M msg_type 0x21 (oml.c:100) 20260125095301138 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): Sending FOM NACK with cause Invalid message type value (oml.c:789) 20260125095301179 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:33995){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095301179 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095301179 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095301179 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095301180 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095301180 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095301180 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095301180 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095301180 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095301180 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095301180 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095301180 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095301180 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095306180 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095306180 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095306189 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095306190 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095306191 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095306192 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095306194 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095306195 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Short OML message: 7 < 9 (oml.c:96)  (oml.c:100) 20260125095306225 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:39481){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095306225 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095306225 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095306225 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095306225 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095306225 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095306225 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095306225 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095306225 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095306226 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095306226 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095306226 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095306226 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095311226 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095311226 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095311234 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095311235 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095311236 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095311237 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095311238 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095311239 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): OML message with 2 extraneous bytes at end: (L1=data-3) [L2]> 80 80 00 07 [L3]> 69 01 00 ff ff 04 01 04 02 (oml.c:1548) 20260125095311239 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): ADM state already was Locked (oml.c:1486) 20260125095311289 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:42575){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095311289 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095311289 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095311289 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095311289 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095311289 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095311289 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095311289 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095311289 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095311290 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095311290 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095311290 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095311290 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095316290 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095316290 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095316297 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095316298 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095316299 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095316300 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095316301 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095316303 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260125095316336 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260125095316337 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260125095316338 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44159){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095316338 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095316338 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095316338 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095316338 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095316338 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095316338 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095316338 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095316338 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095316338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095316338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095316338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095316338 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095321339 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095321339 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095321341 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095321341 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095321341 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095321341 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095321342 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095321342 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260125095321366 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40823){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095321366 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095321366 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095321366 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095321366 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095321366 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095321366 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095321366 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095321366 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095321367 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095321367 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095321367 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095321367 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095326367 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095326367 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095326369 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095326369 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095326370 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095326370 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095326370 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095326370 DOML NOTICE OC=unknown 0xff(ff) INST=(00,ff,ff): Sending FOM NACK with cause Object class not supported (oml.c:789) 20260125095326390 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:39527){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095326390 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095326390 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095326390 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095326390 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095326390 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095326390 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095326390 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095326390 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095326391 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095326391 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095326391 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095326391 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095331391 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095331392 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095331401 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095331402 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095331403 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095331404 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095331405 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095331407 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unexpected BTS 250 in formatted O&M Change Administrative State (exp. 0 or 0xFF) (oml.c:100) 20260125095331407 DOML NOTICE OC=BTS(01) INST=(fa,ff,ff): Sending FOM NACK with cause BTS no. unknown (oml.c:789) 20260125095331436 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:38181){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095331436 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095331436 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095331436 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095331436 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095331436 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095331436 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095331436 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095331436 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095331437 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095331437 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095331437 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095331437 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095336437 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095336437 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095336445 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095336446 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095336447 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095336448 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095336449 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095336450 DOML NOTICE OC=RADIO-CARRIER(02) INST=(00,fa,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260125095336497 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:35869){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095336497 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095336497 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095336497 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095336497 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095336497 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095336497 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095336497 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095336497 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095336498 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095336498 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095336498 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095336498 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095341498 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095341498 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095341502 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095341503 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095341503 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095341504 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095341504 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095341538 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40705){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095341538 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095341538 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095341538 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095341538 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095341538 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095341538 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095341538 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095341538 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095341539 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095341539 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095341539 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095341539 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095346539 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095346539 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095346546 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095346547 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095346548 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095346549 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095346551 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095346595 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:39117){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095346595 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095346595 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095346595 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095346595 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095346595 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095346595 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095346595 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095346595 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095346596 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095346596 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095346596 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095346596 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095351596 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095351596 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095351603 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095351604 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095351604 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095351604 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095351604 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095351642 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:42555){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095351642 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095351642 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095351642 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095351642 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095351642 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095351642 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095351642 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095351642 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095351642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095351642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095351642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095351642 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095356643 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095356643 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095356645 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095356645 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095356646 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095356646 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095356646 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095356647 DL1C NOTICE (bts=0,trx=0,ts=1) Configured multiframe with 'TCH/F+SACCH' (scheduler.c:1024) 20260125095356665 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55afa12a02f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260125095356666 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:35693){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095356666 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095356666 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095356666 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095356667 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095356667 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095356667 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095356667 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095356667 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095356667 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095356667 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095356667 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095356667 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095401667 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095401667 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095401678 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095401679 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095401680 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095401682 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095401683 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095401684 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55afa12a02f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260125095401743 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:39407){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095401743 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095401743 DABIS FATAL OML link was closed early within 1 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095401743 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095401743 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095401743 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095401743 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095401743 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095401743 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095401744 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095401744 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095401744 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095401744 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095406744 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095406744 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095406754 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095406755 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095406755 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095406756 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095406756 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095406784 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:33193){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095406784 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095406785 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095406785 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095406785 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095406785 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095406785 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095406785 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095406785 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095406786 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095406786 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095406786 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095406786 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095411786 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095411786 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095411794 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095411795 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095411796 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095411797 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095411799 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095411800 DPCU NOTICE PCU socket connected to external PCU (pcu_sock.c:1155) 20260125095411803 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: TC_ipa_osmo_pcu_anr_fwd (oml.c:100) 20260125095411851 DLINP NOTICE SRVCONN(,r=769<->l=/tmp/pcu_sock:23) connection closed with client (stream_srv.c:777) 20260125095411851 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260125095411851 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260125095411851 DPCU ERROR PCUIF connection closed (pcu_sock.c:1095) 20260125095411852 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260125095411852 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260125095411852 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:43409){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095411852 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095411852 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095411852 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095411852 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095411852 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095411852 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095411852 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095411852 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095411853 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095411853 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095411853 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095411853 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095416853 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095416854 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095416862 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260125095416863 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095416864 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095416865 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095416866 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260125095416868 DOML ERROR Rx IPA RSL CONNECT IP=127.0.0.1 PORT=65535 STREAM=0x00 for unknown TRX_NR=200 (oml.c:1880) 20260125095416868 DOML NOTICE OC=BASEBAND-TRANSCEIVER(04) INST=(00,c8,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260125095416903 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:37775){CONNECTED} connection closed with srv (stream_cli.c:567) 20260125095416903 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260125095416903 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260125095416903 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260125095416903 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260125095416903 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095416903 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095416903 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095416903 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260125095416904 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095416904 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095416904 DOML ERROR BTS_SHUTDOWN(bts0)[0x55afa129f150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260125095416904 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260125095421904 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260125095421904 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260125095421905 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:444) 20260125095421905 DABIS ERROR E1L(0) Signalling link down (abis.c:429)