((*)) | / \ OsmoBTS 20260128095353143 DLGLOBAL NOTICE Setting SCHED_RR priority 30 (cpu_sched_vty.c:471) 20260128095353145 DLGLOBAL NOTICE Setting up GSMTAP Um forwarding '(null)'->'127.0.0.1:4729' (main.c:363) 20260128095353145 DLCTRL NOTICE CTRL at 127.0.0.1 4238 (control_if.c:1026) 20260128095353145 DLGLOBAL NOTICE Available via telnet 127.0.0.1 4241 (telnet_interface.c:88) 20260128095353145 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.11) in progress... (abis.c:170) 20260128095353145 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.11:3002 (ipaccess.c:1079) 20260128095353146 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095353146 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095353147 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095353147 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095353147 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:446) 20260128095353147 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095358149 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095358149 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095358157 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095358199 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown O&M msg_disc 0x40 (oml.c:96)  (oml.c:100) 20260128095358203 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:35023){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095358203 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095358203 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095358203 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095358204 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095358204 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095358204 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095358204 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095358204 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095358205 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095358205 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095358205 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095358205 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095403206 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095403206 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095403215 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095403216 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095403217 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095403218 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095403219 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095403221 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown Formatted O&M msg_type 0x21 (oml.c:100) 20260128095403221 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): Sending FOM NACK with cause Invalid message type value (oml.c:789) 20260128095403267 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44979){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095403267 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095403267 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095403267 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095403267 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095403267 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095403267 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095403267 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095403267 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095403268 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095403268 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095403268 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095403268 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095408269 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095408269 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095408276 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095408277 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095408278 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095408279 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095408280 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095408281 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Short OML message: 7 < 9 (oml.c:96)  (oml.c:100) 20260128095408337 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:41181){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095408338 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095408338 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095408338 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095408338 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095408338 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095408338 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095408338 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095408338 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095408338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095408338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095408338 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095408338 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095413339 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095413339 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095413347 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095413348 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095413349 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095413350 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095413351 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095413353 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): OML message with 2 extraneous bytes at end: (L1=data-3) [L2]> 80 80 00 07 [L3]> 69 01 00 ff ff 04 01 04 02 (oml.c:1548) 20260128095413353 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): ADM state already was Locked (oml.c:1486) 20260128095413387 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:41785){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095413387 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095413387 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095413387 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095413388 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095413388 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095413388 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095413388 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095413388 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095413388 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095413388 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095413388 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095413388 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095418389 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095418389 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095418397 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095418398 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095418399 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095418400 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095418401 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095418403 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260128095418457 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260128095418458 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260128095418458 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:45383){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095418458 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095418459 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095418459 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095418459 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095418459 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095418459 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095418459 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095418459 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095418459 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095418459 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095418459 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095418459 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095423460 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095423460 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095423468 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095423469 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095423471 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095423472 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095423473 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095423475 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260128095423509 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:43163){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095423509 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095423509 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095423509 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095423509 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095423509 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095423509 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095423509 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095423509 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095423510 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095423510 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095423510 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095423510 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095428511 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095428511 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095428518 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095428518 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095428520 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095428521 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095428522 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095428524 DOML NOTICE OC=unknown 0xff(ff) INST=(00,ff,ff): Sending FOM NACK with cause Object class not supported (oml.c:789) 20260128095428547 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44877){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095428547 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095428547 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095428547 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095428547 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095428547 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095428547 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095428547 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095428547 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095428547 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095428547 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095428547 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095428547 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095433549 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095433549 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095433557 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095433557 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095433558 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095433558 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095433558 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095433558 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unexpected BTS 250 in formatted O&M Change Administrative State (exp. 0 or 0xFF) (oml.c:100) 20260128095433558 DOML NOTICE OC=BTS(01) INST=(fa,ff,ff): Sending FOM NACK with cause BTS no. unknown (oml.c:789) 20260128095433586 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:41281){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095433586 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095433586 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095433586 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095433586 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095433586 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095433586 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095433586 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095433586 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095433587 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095433587 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095433587 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095433587 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095438588 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095438588 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095438596 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095438597 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095438598 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095438599 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095438600 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095438602 DOML NOTICE OC=RADIO-CARRIER(02) INST=(00,fa,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260128095438641 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:36821){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095438641 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095438641 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095438641 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095438641 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095438641 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095438641 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095438641 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095438641 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095438642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095438642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095438642 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095438642 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095443643 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095443643 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095443652 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095443653 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095443654 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095443655 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095443656 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095443689 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44949){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095443689 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095443689 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095443689 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095443689 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095443689 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095443689 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095443689 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095443689 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095443690 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095443690 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095443690 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095443690 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095448690 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095448690 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095448694 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095448694 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095448695 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095448695 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095448695 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095448723 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:41711){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095448723 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095448723 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095448723 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095448724 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095448724 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095448724 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095448724 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095448724 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095448724 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095448724 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095448724 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095448724 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095453725 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095453725 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095453734 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095453735 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095453736 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095453737 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095453738 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095453779 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40563){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095453779 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095453779 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095453779 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095453779 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095453779 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095453779 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095453779 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095453779 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095453780 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095453780 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095453780 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095453780 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095458781 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095458781 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095458789 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095458790 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095458791 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095458792 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095458793 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095458794 DL1C NOTICE (bts=0,trx=0,ts=1) Configured multiframe with 'TCH/F+SACCH' (scheduler.c:1024) 20260128095458835 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55a8807b92f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260128095458836 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:36697){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095458836 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095458836 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095458836 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095458837 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095458837 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095458837 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095458837 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095458837 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095458837 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095458837 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095458837 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095458837 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095503838 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095503838 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095503843 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095503844 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095503844 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095503845 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095503846 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095503847 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55a8807b92f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260128095503869 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:38787){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095503869 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095503869 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095503869 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095503869 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095503869 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095503869 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095503869 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095503869 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095503869 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095503869 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095503870 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095503870 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095508871 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095508871 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095508877 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095508878 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095508880 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095508881 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095508882 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095508920 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:34537){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095508920 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095508920 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095508920 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095508921 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095508921 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095508921 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095508921 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095508921 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095508923 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095508923 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095508923 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095508923 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095513924 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095513924 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095513933 DPCU NOTICE PCU socket connected to external PCU (pcu_sock.c:1155) 20260128095513933 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095513934 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095513936 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095513937 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095513938 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095513947 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: TC_ipa_osmo_pcu_anr_fwd (oml.c:100) 20260128095513985 DLINP NOTICE SRVCONN(,r=769<->l=/tmp/pcu_sock:14) connection closed with client (stream_srv.c:779) 20260128095513985 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260128095513985 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260128095513985 DPCU ERROR PCUIF connection closed (pcu_sock.c:1095) 20260128095513985 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260128095513985 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260128095513985 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44481){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095513985 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095513985 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095513985 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095513986 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095513986 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095513986 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095513986 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095513986 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095513986 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095513986 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095513986 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095513986 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095518987 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095518987 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095518994 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260128095518995 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095518996 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095518998 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095518999 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260128095519000 DOML ERROR Rx IPA RSL CONNECT IP=127.0.0.1 PORT=65535 STREAM=0x00 for unknown TRX_NR=200 (oml.c:1880) 20260128095519000 DOML NOTICE OC=BASEBAND-TRANSCEIVER(04) INST=(00,c8,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260128095519042 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44565){CONNECTED} connection closed with srv (stream_cli.c:569) 20260128095519042 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260128095519042 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260128095519042 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260128095519042 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260128095519042 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095519042 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095519042 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095519043 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260128095519043 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095519043 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095519043 DOML ERROR BTS_SHUTDOWN(bts0)[0x55a8807b8150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260128095519043 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260128095524043 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260128095524043 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260128095524044 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:446) 20260128095524044 DABIS ERROR E1L(0) Signalling link down (abis.c:429)