((*)) | / \ OsmoBTS 20260129095423895 DLGLOBAL NOTICE Setting SCHED_RR priority 30 (cpu_sched_vty.c:471) 20260129095423899 DLGLOBAL NOTICE Setting up GSMTAP Um forwarding '(null)'->'127.0.0.1:4729' (main.c:363) 20260129095423899 DLCTRL NOTICE CTRL at 127.0.0.1 4238 (control_if.c:1026) 20260129095423899 DLGLOBAL NOTICE Available via telnet 127.0.0.1 4241 (telnet_interface.c:88) 20260129095423900 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.11) in progress... (abis.c:170) 20260129095423900 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.11:3002 (ipaccess.c:1079) 20260129095423901 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095423903 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095423905 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095423906 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095423906 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:446) 20260129095423906 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095428908 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095428908 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095428917 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095428920 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown O&M msg_disc 0x40 (oml.c:96)  (oml.c:100) 20260129095428948 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44715){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095428948 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095428948 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095428948 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095428948 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095428948 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095428948 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095428948 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095428948 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095428949 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095428949 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095428949 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095428949 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095433950 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095433950 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095433959 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095433960 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095433961 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095433962 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095433964 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095433965 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: unknown Formatted O&M msg_type 0x21 (oml.c:100) 20260129095433965 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): Sending FOM NACK with cause Invalid message type value (oml.c:789) 20260129095434009 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:38201){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095434009 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095434009 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095434009 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095434009 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095434009 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095434009 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095434009 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095434009 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095434010 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095434010 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095434010 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095434010 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095439011 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095439011 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095439020 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095439021 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095439022 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095439023 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095439025 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095439026 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Short OML message: 7 < 9 (oml.c:96)  (oml.c:100) 20260129095439059 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:34573){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095439059 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095439059 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095439059 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095439060 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095439060 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095439060 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095439060 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095439060 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095439060 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095439060 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095439060 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095439060 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095444061 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095444061 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095444069 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095444070 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095444071 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095444072 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095444073 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095444075 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): OML message with 2 extraneous bytes at end: (L1=data-3) [L2]> 80 80 00 07 [L3]> 69 01 00 ff ff 04 01 04 02 (oml.c:1548) 20260129095444075 DOML NOTICE OC=BTS(01) INST=(00,ff,ff): ADM state already was Locked (oml.c:1486) 20260129095444132 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:44179){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095444132 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095444132 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095444132 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095444132 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095444132 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095444132 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095444132 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095444132 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095444132 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095444132 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095444132 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095444132 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095449134 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095449134 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095449142 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095449143 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095449144 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095449145 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095449146 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095449148 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260129095449181 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260129095449181 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260129095449182 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:42561){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095449182 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095449182 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095449182 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095449182 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095449182 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095449183 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095449183 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095449183 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095449183 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095449183 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095449183 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095449183 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095454184 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095454184 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095454191 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095454192 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095454192 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095454192 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095454193 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095454193 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unsupported segmented O&M message (oml.c:96)  (oml.c:100) 20260129095454245 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:35649){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095454245 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095454245 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095454245 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095454245 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095454245 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095454245 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095454245 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095454245 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095454246 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095454246 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095454246 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095454246 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095459247 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095459247 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095459256 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095459257 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095459258 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095459259 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095459260 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095459261 DOML NOTICE OC=unknown 0xff(ff) INST=(00,ff,ff): Sending FOM NACK with cause Object class not supported (oml.c:789) 20260129095459309 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40641){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095459309 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095459309 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095459309 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095459310 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095459310 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095459310 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095459310 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095459310 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095459310 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095459310 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095459310 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095459310 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095504310 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095504311 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095504312 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095504313 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095504313 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095504313 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095504313 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095504314 DOML NOTICE OC=BTS INST=(00,ff,ff): Sending Process stopped to BSC: Unexpected BTS 250 in formatted O&M Change Administrative State (exp. 0 or 0xFF) (oml.c:100) 20260129095504314 DOML NOTICE OC=BTS(01) INST=(fa,ff,ff): Sending FOM NACK with cause BTS no. unknown (oml.c:789) 20260129095504348 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:37835){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095504348 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095504348 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095504348 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095504348 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095504348 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095504348 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095504348 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095504348 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095504348 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095504348 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095504348 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095504348 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095509350 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095509350 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095509352 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095509352 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095509352 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095509352 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095509352 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095509353 DOML NOTICE OC=RADIO-CARRIER(02) INST=(00,fa,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260129095509381 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40355){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095509381 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095509381 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095509381 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095509381 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095509381 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095509381 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095509381 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095509381 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095509382 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095509382 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095509382 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095509382 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095514383 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095514383 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095514390 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095514390 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095514391 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095514392 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095514393 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095514439 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:35907){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095514439 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095514439 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095514439 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095514439 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095514439 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095514439 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095514440 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095514440 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095514440 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095514440 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095514440 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095514440 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095519441 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095519441 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095519445 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095519445 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095519446 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095519446 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095519446 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095519468 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:33781){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095519468 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095519468 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095519468 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095519468 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095519468 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095519468 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095519468 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095519468 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095519469 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095519469 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095519469 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095519469 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095524469 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095524469 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095524471 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095524471 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095524472 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095524472 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095524472 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095524495 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:37793){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095524495 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095524495 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095524495 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095524495 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095524495 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095524495 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095524495 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095524495 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095524496 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095524496 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095524496 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095524496 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095529497 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095529497 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095529503 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095529504 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095529506 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095529507 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095529508 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095529510 DL1C NOTICE (bts=0,trx=0,ts=1) Configured multiframe with 'TCH/F+SACCH' (scheduler.c:1024) 20260129095529555 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55c4091822f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260129095529557 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:36605){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095529557 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095529557 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095529557 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095529557 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095529557 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095529557 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095529557 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095529557 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095529557 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095529557 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095529557 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095529557 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095534558 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095534558 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095534564 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095534565 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095534566 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095534566 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095534567 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095534568 DOML NOTICE NM_CHAN_OP(bts0-trx0-ts1)[0x55c4091822f0]{DISABLED_DEPENDENCY}: BSC trying to activate TS while still in avail=dependency. Allowing it to stay backward-compatible with older osmo-bts versions, but BSC is wrong. (nm_channel_fsm.c:116) 20260129095534629 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:40827){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095534630 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095534630 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095534630 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095534630 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095534630 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095534630 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095534630 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095534630 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095534631 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095534631 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095534631 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095534631 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095539631 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095539632 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095539638 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095539638 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095539639 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095539640 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095539641 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095539710 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:33533){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095539710 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095539710 DABIS FATAL OML link was closed early within 1 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095539710 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095539711 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095539711 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095539711 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095539711 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095539711 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095539713 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095539713 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095539713 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095539713 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095544713 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095544714 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095544716 DPCU NOTICE PCU socket connected to external PCU (pcu_sock.c:1155) 20260129095544716 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095544716 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095544717 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095544717 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095544717 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095544720 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: TC_ipa_osmo_pcu_anr_fwd (oml.c:100) 20260129095544780 DLINP NOTICE SRVCONN(,r=769<->l=/tmp/pcu_sock:14) connection closed with client (stream_srv.c:779) 20260129095544780 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260129095544780 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260129095544780 DPCU ERROR PCUIF connection closed (pcu_sock.c:1095) 20260129095544780 DPCU NOTICE PCU socket has LOST connection (pcu_sock.c:1057) 20260129095544780 DOML NOTICE OC=GPRS-CELL INST=(00,00,ff): Sending PCU version report to BSC: PCU socket has LOST connection (oml.c:100) 20260129095544781 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:34403){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095544781 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095544781 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095544781 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095544781 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095544781 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095544781 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095544781 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095544781 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095544783 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095544783 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095544783 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095544783 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095549784 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095549784 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095549792 DLINP NOTICE received ID_GET for unit ID 1234/0/0 (ipaccess.c:901) 20260129095549792 DTRX NOTICE phy0.0: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095549794 DTRX NOTICE phy0.1: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095549795 DTRX NOTICE phy0.2: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095549796 DTRX NOTICE phy0.3: Opening TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1291) 20260129095549797 DOML ERROR Rx IPA RSL CONNECT IP=127.0.0.1 PORT=65535 STREAM=0x00 for unknown TRX_NR=200 (oml.c:1880) 20260129095549797 DOML NOTICE OC=BASEBAND-TRANSCEIVER(04) INST=(00,c8,ff): Sending FOM NACK with cause Baseband Transceiver no. unknown (oml.c:789) 20260129095549851 DLINP NOTICE CLICONN(ts-0-1-oml,r=127.0.0.1:3002<->l=127.0.0.1:33527){CONNECTED} connection closed with srv (stream_cli.c:569) 20260129095549851 DABIS ERROR E1L(0) Signalling link down (abis.c:429) 20260129095549851 DABIS FATAL OML link was closed early within 0 seconds. If this situation persists, please check your BTS and BSC configuration files for errors. A common error is a mismatch between unit_id configuration parameters of BTS and BSC. (abis.c:105) 20260129095549851 DOML NOTICE BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Shutting down BTS, exit 0, reason: Abis close (bts_shutdown_fsm.c:268) 20260129095549852 DL1C NOTICE GSM clock stopped (scheduler_trx.c:510) 20260129095549852 DTRX NOTICE phy0.0: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095549852 DTRX NOTICE phy0.1: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095549852 DTRX NOTICE phy0.2: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095549852 DTRX NOTICE phy0.3: Closing TRXC/TRXD connections to 127.0.0.1 (trx_if.c:1239) 20260129095549854 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095549854 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095549854 DOML ERROR BTS_SHUTDOWN(bts0)[0x55c409181150]{NONE}: Event BTS_SHUTDOWN_EV_TRX_CLOSED not permitted (bts_shutdown_fsm.c:282) 20260129095549854 DLINP NOTICE E1TS(0:1) failed reading from socket: 0 (ipaccess.c:934) 20260129095554854 DABIS NOTICE A-bis connection establishment to BSC (127.0.0.1) in progress... (abis.c:170) 20260129095554854 DLINP NOTICE E1TS(0:1) enabling ipaccess BTS mode, OML connecting to 127.0.0.1:3002 (ipaccess.c:1079) 20260129095554855 DLINP ERROR CLICONN(ts-0-1-oml,){CONNECTING} connect failed (-111) (stream_cli.c:446) 20260129095554855 DABIS ERROR E1L(0) Signalling link down (abis.c:429)