Failed
nitb_sms:trx-lms-limenet-micro.mo_mt_sms.py (from nitb_sms_trx-lms-limenet-micro)
Stacktrace
osmo-nitb_10.42.42.2(pid=27777): Process ended prematurely: osmo-nitb_10.42.42.2(pid=27777) [trial-2358↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=27777)]
Standard Output
---------------------------------------------- trial-2358 nitb_sms:trx-lms-limenet-micro mo_mt_sms.py ---------------------------------------------- 10:43:17.601376 tst nitb_sms:trx-lms-limenet-micro: Using 1 x ip_address (candidates: 1) 10:43:17.611963 tst nitb_sms:trx-lms-limenet-micro: Using 1 x bts (candidates: 1) 10:43:17.750882 tst mo_mt_sms.py: using LAC 20910 10:43:17.879132 tst mo_mt_sms.py: using RAC 255 10:43:18.002789 tst mo_mt_sms.py: using CellId 20910 10:43:18.125793 tst mo_mt_sms.py: using BVCI 20911 10:43:18.150156 tst nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2) 10:43:18.267212 tst nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2) 10:43:18.555309 tst mo_mt_sms.py:9: start nitb and bts... 10:43:18.688196 run osmo-nitb_10.42.42.2: Starting osmo-nitb 10:43:19.347357 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=27776): Launched 10:43:19.664301 run osmo-nitb_10.42.42.2(pid=27777): Launched 10:43:19.859764 run osmo-nitb_10.42.42.2(pid=27777): ERR: Terminated: ERROR {rc=2} [trial-2358↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=27777)] 10:43:20.003570 run osmo-nitb_10.42.42.2(pid=27777): stdout: | (launched: 2022-12-09_10:43:19.510124) 10:43:20.147511 run osmo-nitb_10.42.42.2(pid=27777): stderr: | (launched: 2022-12-09_10:43:19.557456) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 10:43:20.287132 run osmo-nitb_10.42.42.2(pid=27777): stdout: | (launched: 2022-12-09_10:43:19.510124) 10:43:20.426774 run osmo-nitb_10.42.42.2(pid=27777): stderr: | (launched: 2022-12-09_10:43:19.557456) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 10:43:20.792243 tst osmo-nitb_10.42.42.2(pid=27777): stdout: | (launched: 2022-12-09_10:43:19.510124) 10:43:20.919190 tst osmo-nitb_10.42.42.2(pid=27777): stderr: | (launched: 2022-12-09_10:43:19.557456) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 10:43:20.974577 tst mo_mt_sms.py:11: ERR: Error: osmo-nitb_10.42.42.2(pid=27777): Process ended prematurely: osmo-nitb_10.42.42.2(pid=27777) [trial-2358↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=27777)] [trial-2358↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11] 10:43:20.983368 tst mo_mt_sms.py:11: Test FAILED (3.4 sec) 10:43:21.021805 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=27776): Terminating (SIGTERM) 10:43:21.199641 --- ParallelTerminationStrategy: PID 27776 died... 10:43:21.258895 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=27776): Terminated: ok {rc=0} 10:43:21.346781 bus /sierra_3: Setting Powered False 10:43:22.456412 bus /sierra_3: Setting Powered False 10:43:23.570430 bus /sierra_2: Setting Powered False
Standard Error
Traceback (most recent call last): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run self.path) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file spec.loader.exec_module( importlib.util.module_from_spec(spec) ) File "<frozen importlib._bootstrap_external>", line 728, in exec_module File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/nitb_sms/mo_mt_sms.py", line 11, in <module> nitb.start() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/nitb_osmo.py", line 67, in start self.ctrl.connect() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/osmo_ctrl.py", line 92, in connect MainLoop.wait(self.try_connect, timestep=3, timeout=timeout) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise self.poll(may_block=True) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll self.deferred_handling.handle_queue() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue handler(*args, **kwargs) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll raise log_module.Error('Process ended prematurely: %s' % proc.name()) osmo_gsm_tester.core.log.Error: osmo-nitb_10.42.42.2(pid=27777): Process ended prematurely: osmo-nitb_10.42.42.2(pid=27777) [trial-2358↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=27777)]