Failed
nitb_sms:trx-lms-limenet-micro.mo_mt_sms.py (from nitb_sms_trx-lms-limenet-micro)
Stacktrace
osmo-nitb_10.42.42.2(pid=16647): Process ended prematurely: osmo-nitb_10.42.42.2(pid=16647) [trial-2368↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=16647)]
Standard Output
---------------------------------------------- trial-2368 nitb_sms:trx-lms-limenet-micro mo_mt_sms.py ---------------------------------------------- 03:00:04.278099 tst nitb_sms:trx-lms-limenet-micro: Using 1 x ip_address (candidates: 1) 03:00:04.289440 tst nitb_sms:trx-lms-limenet-micro: Using 1 x bts (candidates: 1) 03:00:04.431585 tst mo_mt_sms.py: using LAC 25520 03:00:04.556104 tst mo_mt_sms.py: using RAC 20 03:00:04.680019 tst mo_mt_sms.py: using CellId 25520 03:00:04.805355 tst mo_mt_sms.py: using BVCI 25521 03:00:04.829575 tst nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2) 03:00:04.946917 tst nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2) 03:00:05.238205 tst mo_mt_sms.py:9: start nitb and bts... 03:00:05.372170 run osmo-nitb_10.42.42.2: Starting osmo-nitb 03:00:06.030660 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=16646): Launched 03:00:06.346463 run osmo-nitb_10.42.42.2(pid=16647): Launched 03:00:06.542610 run osmo-nitb_10.42.42.2(pid=16647): ERR: Terminated: ERROR {rc=2} [trial-2368↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=16647)] 03:00:06.687278 run osmo-nitb_10.42.42.2(pid=16647): stdout: | (launched: 2022-12-10_03:00:06.192623) 03:00:06.831063 run osmo-nitb_10.42.42.2(pid=16647): stderr: | (launched: 2022-12-10_03:00:06.240326) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 03:00:06.970658 run osmo-nitb_10.42.42.2(pid=16647): stdout: | (launched: 2022-12-10_03:00:06.192623) 03:00:07.109691 run osmo-nitb_10.42.42.2(pid=16647): stderr: | (launched: 2022-12-10_03:00:06.240326) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 03:00:07.474486 tst osmo-nitb_10.42.42.2(pid=16647): stdout: | (launched: 2022-12-10_03:00:06.192623) 03:00:07.602367 tst osmo-nitb_10.42.42.2(pid=16647): stderr: | (launched: 2022-12-10_03:00:06.240326) | ====================================================================== | ERROR: You should not run osmo-nitb. It is ancient, unmaintained and | obsolete for several years. If you really want to ignore years of hard work on | the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp), | you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line | argument. DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!! | Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box | ====================================================================== 03:00:07.657814 tst mo_mt_sms.py:11: ERR: Error: osmo-nitb_10.42.42.2(pid=16647): Process ended prematurely: osmo-nitb_10.42.42.2(pid=16647) [trial-2368↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=16647)] [trial-2368↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11] 03:00:07.666395 tst mo_mt_sms.py:11: Test FAILED (3.4 sec) 03:00:07.702080 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=16646): Terminating (SIGTERM) 03:00:07.879768 --- ParallelTerminationStrategy: PID 16646 died... 03:00:07.937254 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=16646): Terminated: ok {rc=0} 03:00:08.025516 bus /sierra_3: Setting Powered False 03:00:09.132673 bus /sierra_3: Setting Powered False 03:00:10.242054 bus /sierra_2: Setting Powered False
Standard Error
Traceback (most recent call last): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run self.path) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file spec.loader.exec_module( importlib.util.module_from_spec(spec) ) File "<frozen importlib._bootstrap_external>", line 728, in exec_module File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/nitb_sms/mo_mt_sms.py", line 11, in <module> nitb.start() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/nitb_osmo.py", line 67, in start self.ctrl.connect() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/osmo_ctrl.py", line 92, in connect MainLoop.wait(self.try_connect, timestep=3, timeout=timeout) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep): File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise self.poll(may_block=True) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll self.deferred_handling.handle_queue() File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue handler(*args, **kwargs) File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll raise log_module.Error('Process ended prematurely: %s' % proc.name()) osmo_gsm_tester.core.log.Error: osmo-nitb_10.42.42.2(pid=16647): Process ended prematurely: osmo-nitb_10.42.42.2(pid=16647) [trial-2368↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=16647)]