trial-2352 nitb_sms:trx-b200 mo_mt_sms.py
----------------------------------------------
00:58:40.075047 tst                nitb_sms:trx-b200: Using 1 x ip_address (candidates: 1)
00:58:40.086348 tst                nitb_sms:trx-b200: Using 1 x bts (candidates: 1)
00:58:40.228554 tst                     mo_mt_sms.py: using LAC 17960
00:58:40.354077 tst                     mo_mt_sms.py: using RAC 110
00:58:40.478327 tst                     mo_mt_sms.py: using CellId 17960
00:58:40.607191 tst                     mo_mt_sms.py: using BVCI 17961
00:58:40.631349 tst                nitb_sms:trx-b200: Using 1 x modem (candidates: 2)
00:58:40.750551 tst                nitb_sms:trx-b200: Using 1 x modem (candidates: 2)
00:58:41.023043 tst                   mo_mt_sms.py:9: start nitb and bts...
00:58:41.146449 run             osmo-nitb_10.42.42.2: Starting osmo-nitb
00:58:41.764760 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=4304): Launched
00:58:42.060902 run   osmo-nitb_10.42.42.2(pid=4305): Launched
00:58:42.244696 run   osmo-nitb_10.42.42.2(pid=4305): ERR: Terminated: ERROR {rc=2}  [trial-2352↪nitb_sms:trx-b200↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=4305)]
00:58:42.380475 run   osmo-nitb_10.42.42.2(pid=4305): stdout: 
| (launched: 2022-12-09_00:58:41.915855) 
00:58:42.516632 run   osmo-nitb_10.42.42.2(pid=4305): stderr: 
| (launched: 2022-12-09_00:58:41.960142)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
00:58:42.647917 run   osmo-nitb_10.42.42.2(pid=4305): stdout: 
| (launched: 2022-12-09_00:58:41.915855) 
00:58:42.778237 run   osmo-nitb_10.42.42.2(pid=4305): stderr: 
| (launched: 2022-12-09_00:58:41.960142)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
00:58:43.180537 tst   osmo-nitb_10.42.42.2(pid=4305): stdout: 
| (launched: 2022-12-09_00:58:41.915855) 
00:58:43.299030 tst   osmo-nitb_10.42.42.2(pid=4305): stderr: 
| (launched: 2022-12-09_00:58:41.960142)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
00:58:43.350827 tst                  mo_mt_sms.py:11: ERR: Error: osmo-nitb_10.42.42.2(pid=4305): Process ended prematurely: osmo-nitb_10.42.42.2(pid=4305) [trial-2352↪nitb_sms:trx-b200↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=4305)]  [trial-2352↪nitb_sms:trx-b200↪mo_mt_sms.py:11]
00:58:43.358877 tst                  mo_mt_sms.py:11: Test FAILED (3.3 sec)
00:58:43.394122 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=4304): Terminating (SIGTERM)
00:58:43.571750 ---      ParallelTerminationStrategy: PID 4304 died...
00:58:43.627308 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=4304): Terminated: ok {rc=0}
00:58:43.716006 bus                        /sierra_3: Setting Powered False
00:58:44.821565 bus                        /sierra_3: Setting Powered False
00:58:45.944433 bus                        /sierra_2: Setting Powered False