    Repository: $GERRIT_REPO_URL
    • master
    l1sap: fix duplicate RF RESOURCE INDICATION on clock bootstrap

    The TTCN-3 test suite (ttcn3-bts-test) expects to receive exactly one
    RF RESOURCE INDICATION message from each TRX during the bootstrap stage,
    while waiting for all TRX to come up and be configured by the BSC.

    l1sap_interf_meas_report() fires whenever bts->gsm_time.fn % period is
    0, where period = intave * 104 (typically 624 frames).  Since CLCK.ind
    with FN=0 satisfies this condition, a report is sent at the very
    beginning of each clock epoch.

    This was not a problem before commit fcfc4e83, because the first
    CLCK.ind from the transciever was effectively a no-op: with
    last_fn_timer.fn zero-initialised, the first indication at FN=0 yielded
    elapsed_fn=0 (not > MAX_FN_SKEW), and the catch-up loop (while fn !=
    last_fn_timer.fn) would not execute either.  Downlink scheduling only
    started on the second CLCK.ind (at FN=102, which is > MAX_FN_SKEW),
    and 102 % 624 != 0, so no RF RESOURCE INDICATION was triggered.

    fcfc4e83 changed the logic so that Downlink scheduling now begins
    immediately on the first CLCK.ind, via an unconditional call to
    trx_setup_clock() -> bts_sched_fn(fn).  When fake_trx starts its frame
    counter from FN=0, this immediately triggers l1sap_interf_meas_report()
    because 0 % 624 == 0.  A second report follows ~2.88s later when the
    periodic timer reaches FN=624, making the bootstrap logic
    in ttcn3-bts-test unhappy.

    Fix by shifting the trigger to (fn + 1) % period == 0, i.e. the report
    fires at the last frame of each period rather than the first.  FN=0 now
    yields (0+1) % 624 = 1 != 0, suppressing the spurious bootstrap report.
    The periodic behaviour and report cadence are otherwise unchanged.

    Change-Id: I6550178427b08e67c9763f0f37efff5b88960b1f
    Related: fcfc4e83 ("osmo-bts-trx: fix spurious shutdown on first CLCK.ind from osmo-trx")
    AI-Assisted: yes (Claude)