7cf992bd48561a31127c33bdb439ca089a272515
by Vadim Yanitskiypower_control: always feed input values to do_avg_algo()
The purpose of the power control interval (P_CON_INTERVAL) is to
temporarily suspend the decision-making process of the MS/BS power
control algorithm, allowing time to observe the effects of a
previous adjustment.
However, input value (RxLev/RxQual) averaging must continue
uninterrupted, regardless of the power control interval.
Otherwise we're simply loosing measurement samples.
Change-Id: I2ccad1cb0ebbfcce64a93bc81b66db37b1399769