Skip to content

Failed

nitb_sms:trx-lms-limenet-micro.mo_mt_sms.py (from nitb_sms_trx-lms-limenet-micro)

Failing for the past 216 builds (Since #2140 )
Took 4 sec.

Stacktrace

osmo-nitb_10.42.42.2(pid=1485): Process ended prematurely: osmo-nitb_10.42.42.2(pid=1485) [trial-2355↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=1485)]

Standard Output

----------------------------------------------
trial-2355 nitb_sms:trx-lms-limenet-micro mo_mt_sms.py
----------------------------------------------
06:20:47.044003 tst   nitb_sms:trx-lms-limenet-micro: Using 1 x ip_address (candidates: 1)
06:20:47.059167 tst   nitb_sms:trx-lms-limenet-micro: Using 1 x bts (candidates: 1)
06:20:47.214746 tst                     mo_mt_sms.py: using LAC 19527
06:20:47.338736 tst                     mo_mt_sms.py: using RAC 147
06:20:47.451747 tst                     mo_mt_sms.py: using CellId 19527
06:20:47.563804 tst                     mo_mt_sms.py: using BVCI 19528
06:20:47.585977 tst   nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2)
06:20:47.703333 tst   nitb_sms:trx-lms-limenet-micro: Using 1 x modem (candidates: 2)
06:20:47.989881 tst                   mo_mt_sms.py:9: start nitb and bts...
06:20:48.120792 run             osmo-nitb_10.42.42.2: Starting osmo-nitb
06:20:48.767649 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=1484): Launched
06:20:49.074781 run   osmo-nitb_10.42.42.2(pid=1485): Launched
06:20:49.267615 run   osmo-nitb_10.42.42.2(pid=1485): ERR: Terminated: ERROR {rc=2}  [trial-2355↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=1485)]
06:20:49.410349 run   osmo-nitb_10.42.42.2(pid=1485): stdout: 
| (launched: 2022-12-09_06:20:48.926378) 
06:20:49.553161 run   osmo-nitb_10.42.42.2(pid=1485): stderr: 
| (launched: 2022-12-09_06:20:48.972840)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
06:20:49.691087 run   osmo-nitb_10.42.42.2(pid=1485): stdout: 
| (launched: 2022-12-09_06:20:48.926378) 
06:20:49.827814 run   osmo-nitb_10.42.42.2(pid=1485): stderr: 
| (launched: 2022-12-09_06:20:48.972840)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
06:20:50.200198 tst   osmo-nitb_10.42.42.2(pid=1485): stdout: 
| (launched: 2022-12-09_06:20:48.926378) 
06:20:50.324765 tst   osmo-nitb_10.42.42.2(pid=1485): stderr: 
| (launched: 2022-12-09_06:20:48.972840)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
06:20:50.379433 tst                  mo_mt_sms.py:11: ERR: Error: osmo-nitb_10.42.42.2(pid=1485): Process ended prematurely: osmo-nitb_10.42.42.2(pid=1485) [trial-2355↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=1485)]  [trial-2355↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11]
06:20:50.388011 tst                  mo_mt_sms.py:11: Test FAILED (3.3 sec)
06:20:50.423977 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=1484): Terminating (SIGTERM)
06:20:50.601796 ---      ParallelTerminationStrategy: PID 1484 died...
06:20:50.659130 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=1484): Terminated: ok {rc=0}
06:20:50.745451 bus                        /sierra_3: Setting Powered False
06:20:51.849747 bus                        /sierra_3: Setting Powered False
06:20:52.960550 bus                        /sierra_2: Setting Powered False

Standard Error

Traceback (most recent call last):
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run
    self.path)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file
    spec.loader.exec_module( importlib.util.module_from_spec(spec) )
  File "<frozen importlib._bootstrap_external>", line 728, in exec_module
  File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/nitb_sms/mo_mt_sms.py", line 11, in <module>
    nitb.start()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/nitb_osmo.py", line 67, in start
    self.ctrl.connect()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/osmo_ctrl.py", line 92, in connect
    MainLoop.wait(self.try_connect, timestep=3, timeout=timeout)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait
    if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep):
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise
    self.poll(may_block=True)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll
    self.deferred_handling.handle_queue()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue
    handler(*args, **kwargs)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll
    raise log_module.Error('Process ended prematurely: %s' % proc.name())
osmo_gsm_tester.core.log.Error: osmo-nitb_10.42.42.2(pid=1485): Process ended prematurely: osmo-nitb_10.42.42.2(pid=1485) [trial-2355↪nitb_sms:trx-lms-limenet-micro↪mo_mt_sms.py:11↪mo_mt_sms.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=1485)]