Skip to content

Failed

nitb_smpp.esme_connect_policy_closed.py

Failing for the past 233 builds (Since #2172 )
Took 3 sec.

Stacktrace

osmo-nitb_10.42.42.2(pid=23196): Process ended prematurely: osmo-nitb_10.42.42.2(pid=23196) [trial-2404↪nitb_smpp↪esme_connect_policy_closed.py:24↪esme_connect_policy_closed.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=23196)]

Standard Output

----------------------------------------------
trial-2404 nitb_smpp esme_connect_policy_closed.py
----------------------------------------------
12:39:52.325695 tst                        nitb_smpp: Using 1 x ip_address (candidates: 1)
12:39:52.442537 tst    esme_connect_policy_closed.py: using MSISDN 8684
12:39:52.571001 tst    esme_connect_policy_closed.py: using MSISDN 8685
12:39:52.686367 run             osmo-nitb_10.42.42.2: Starting osmo-nitb
12:39:53.300422 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=23195): Launched
12:39:53.625182 run  osmo-nitb_10.42.42.2(pid=23196): Launched
12:39:53.809066 run  osmo-nitb_10.42.42.2(pid=23196): ERR: Terminated: ERROR {rc=2}  [trial-2404↪nitb_smpp↪esme_connect_policy_closed.py:24↪esme_connect_policy_closed.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=23196)]
12:39:53.943397 run  osmo-nitb_10.42.42.2(pid=23196): stdout: 
| (launched: 2022-12-14_12:39:53.465989) 
12:39:54.078261 run  osmo-nitb_10.42.42.2(pid=23196): stderr: 
| (launched: 2022-12-14_12:39:53.514436)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
12:39:54.208182 run  osmo-nitb_10.42.42.2(pid=23196): stdout: 
| (launched: 2022-12-14_12:39:53.465989) 
12:39:54.337463 run  osmo-nitb_10.42.42.2(pid=23196): stderr: 
| (launched: 2022-12-14_12:39:53.514436)
| ======================================================================
| ERROR: You should not run osmo-nitb. It is ancient, unmaintained and
| obsolete for several years.  If you really want to ignore years of hard work on
| the new post-NITB stack (osmo-bsc, osmo-mgw, osmo-msc, osmo-hlr, osmo-stp),
| you may ues the '--yes-i-really-want-to-run-prehistoric-software' command line
| argument.  DON'T EVER BOTHER THE DEVELOPERS IF YOU ENCOUNTER PROBLEMS WITH IT!!!
| Use https://osmocom.org/projects/cellular-infrastructure/wiki/Osmocom_Network_In_The_Box
| ====================================================================== 
12:39:54.394441 tst esme_connect_policy_closed.py:24: ERR: Error: osmo-nitb_10.42.42.2(pid=23196): Process ended prematurely: osmo-nitb_10.42.42.2(pid=23196) [trial-2404↪nitb_smpp↪esme_connect_policy_closed.py:24↪esme_connect_policy_closed.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=23196)]  [trial-2404↪nitb_smpp↪esme_connect_policy_closed.py:24]
12:39:54.402942 tst esme_connect_policy_closed.py:24: Test FAILED (2.1 sec)
12:39:54.438835 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=23195): Terminating (SIGTERM)
12:39:54.616396 ---      ParallelTerminationStrategy: PID 23195 died...
12:39:54.673711 run pcap-recorder_any(filters='host 10.42.42.2 and port not 22')(pid=23195): Terminated: ok {rc=0}

Standard Error

Traceback (most recent call last):
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run
    self.path)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file
    spec.loader.exec_module( importlib.util.module_from_spec(spec) )
  File "<frozen importlib._bootstrap_external>", line 728, in exec_module
  File "<frozen importlib._bootstrap>", line 219, in _call_with_frames_removed
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/sysmocom/suites/nitb_smpp/esme_connect_policy_closed.py", line 24, in <module>
    nitb.start()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/nitb_osmo.py", line 67, in start
    self.ctrl.connect()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/obj/osmo_ctrl.py", line 92, in connect
    MainLoop.wait(self.try_connect, timestep=3, timeout=timeout)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 108, in wait
    if not self.wait_no_raise(condition, condition_args, condition_kwargs, timeout, timestep):
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 98, in wait_no_raise
    self.poll(may_block=True)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 86, in poll
    self.deferred_handling.handle_queue()
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 33, in handle_queue
    handler(*args, **kwargs)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod/osmo-gsm-tester/src/osmo_gsm_tester/testenv.py", line 142, in poll
    raise log_module.Error('Process ended prematurely: %s' % proc.name())
osmo_gsm_tester.core.log.Error: osmo-nitb_10.42.42.2(pid=23196): Process ended prematurely: osmo-nitb_10.42.42.2(pid=23196) [trial-2404↪nitb_smpp↪esme_connect_policy_closed.py:24↪esme_connect_policy_closed.py↪osmo-nitb_10.42.42.2↪osmo-nitb_10.42.42.2(pid=23196)]