Skip to content
Started by user Oliver Smith
Running as SYSTEM
Building remotely on octsimtest in workspace /home/jenkins/workspace/octsim_osmo-ccid-firmware
The recommended git tool is: NONE
No credentials specified
Wiping out workspace first.
Cloning the remote Git repository
Cloning repository https://gerrit.osmocom.org/osmo-ccid-firmware
 > git init /home/jenkins/workspace/octsim_osmo-ccid-firmware # timeout=10
Fetching upstream changes from https://gerrit.osmocom.org/osmo-ccid-firmware
 > git --version # timeout=10
 > git --version # 'git version 2.39.5'
 > git fetch --tags --force --progress -- https://gerrit.osmocom.org/osmo-ccid-firmware +refs/heads/*:refs/remotes/origin/* # timeout=10
 > git config remote.origin.url https://gerrit.osmocom.org/osmo-ccid-firmware # timeout=10
 > git config --add remote.origin.fetch +refs/heads/*:refs/remotes/origin/* # timeout=10
Avoid second fetch
 > git rev-parse refs/remotes/origin/osmith/wip^{commit} # timeout=10
 > git rev-parse osmith/wip^{commit} # timeout=10
Checking out Revision e178050d53270783f16ec210c2f88013bdb5a912 (refs/remotes/origin/osmith/wip)
 > git config core.sparsecheckout # timeout=10
 > git checkout -f e178050d53270783f16ec210c2f88013bdb5a912 # timeout=10
Commit message: "tests: show test script output while running"
First time build. Skipping changelog.
[octsim_osmo-ccid-firmware] $ /bin/sh -xe /tmp/jenkins5666269690564403947.sh
+ export PYTHONUNBUFFERED=1
+ cd ./tests
+ mkdir -p sysmo-octsim/dl
+ timeout 30m ./run-tests
==========================================================
            EXECUTING TESTS FOR SYSMO-OCTSIM
==========================================================

Location /home/jenkins/workspace/octsim_osmo-ccid-firmware/tests/sysmo-octsim

WARNING: tempfile is deprecated; consider using mktemp instead.
================ PREPARING TEST RIG ================
resetting target
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
done
================ TEST RIG PREPARED =================

Prepare done
==> Executing Testcase 01_check_rig.sh

ID 16c0:05df Van Ooijen Technische Informatica HID device except mice, keyboards, and joysticks
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               1.10
  bDeviceClass            0 
  bDeviceSubClass         0 
  bDeviceProtocol         0 
  bMaxPacketSize0         8
  idVendor           0x16c0 Van Ooijen Technische Informatica
  idProduct          0x05df HID device except mice, keyboards, and joysticks
  bcdDevice            1.00
  iManufacturer           1 www.dcttech.com
  iProduct                2 USBRelay2
  iSerial                 0 
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                 9
    bDescriptorType         2
    wTotalLength       0x0022
    bNumInterfaces          1
    bConfigurationValue     1
    iConfiguration          0 
    bmAttributes         0x80
      (Bus Powered)
    MaxPower               20mA
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        0
      bAlternateSetting       0
      bNumEndpoints           1
      bInterfaceClass         3 Human Interface Device
      bInterfaceSubClass      0 
      bInterfaceProtocol      0 
      iInterface              0 
        HID Device Descriptor:
          bLength                 9
          bDescriptorType        33
          bcdHID               1.01
          bCountryCode            0 Not supported
          bNumDescriptors         1
          bDescriptorType        34 Report
          wDescriptorLength      22
         Report Descriptors: 
           ** UNAVAILABLE **
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x81  EP 1 IN
        bmAttributes            3
          Transfer Type            Interrupt
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0008  1x 8 bytes
        bInterval              20
Device Status:     0x0000
  (Bus Powered)
---
Diff with expected output:
---
Test 01_check_rig.sh passed
==> Executing Testcase 02_flash_dfu.sh
installed fw version: 0.3.49-be7b
fetch image
2026-04-14 11:14:06 URL:https://downloads.osmocom.org/binaries/osmo-ccid-firmware/latest/sysmoOCTSIM.bin [66944/66944] -> "dl/sysmoOCTSIM-latest.bin" [1]
done
resetting target to dfu
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
BITFT_1=0
BITFT_2=1
BITFT_1=1
BITFT_2=1
done
dfu-util 0.11

Copyright 2005-2009 Weston Schmidt, Harald Welte and OpenMoko Inc.
Copyright 2010-2021 Tormod Volden and Stefan Schmidt
This program is Free Software and has ABSOLUTELY NO WARRANTY
Please report bugs to http://sourceforge.net/p/dfu-util/tickets/

Opening DFU capable USB device...
Device ID 1d50:6141
Device DFU version 0110
Claiming USB DFU Interface...
Setting Alternate Interface #0 ...
Determining device status...
DFU state(2) = dfuIDLE, status(0) = No error condition is present
DFU mode device DFU version 0110
Device returned transfer size 512
Copying data from PC to DFU device
Download done.
installed fw version: 0.3.49-be7b
---
Diff with expected output:
---
Test 02_flash_dfu.sh passed
==> Executing Testcase 03_check_lsusb.sh

ID 1d50:6141 OpenMoko, Inc. sysmoOCTSIM
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               2.00
  bDeviceClass            0 
  bDeviceSubClass         0 
  bDeviceProtocol         0 
  bMaxPacketSize0        64
  idVendor           0x1d50 OpenMoko, Inc.
  idProduct          0x6141 
  bcdDevice            0.00
  iManufacturer           1 sysmocom - s.f.m.c. GmbH
  iProduct                2 sysmoOCTSIM
  iSerial                 7 ecc68ade3335355320202034463715ff
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                 9
    bDescriptorType         2
    wTotalLength       0x006f
    bNumInterfaces          2
    bConfigurationValue     1
    iConfiguration          3 A
    bmAttributes         0x80
      (Bus Powered)
    MaxPower              500mA
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        0
      bAlternateSetting       0
      bNumEndpoints           3
      bInterfaceClass        11 Chip/SmartCard
      bInterfaceSubClass      0 
      bInterfaceProtocol      0 
      iInterface              6 CCID
      ChipCard Interface Descriptor:
        bLength                54
        bDescriptorType        33
        bcdCCID              1.10  (Warning: Only accurate for version 1.0)
        nMaxSlotIndex           7
        bVoltageSupport         7  5.0V 3.0V 1.8V 
        dwProtocols             1  T=0
        dwDefaultClock       2500
        dwMaxiumumClock     20000
        bNumClockSupported      4
        dwDataRate           6720 bps
        dwMaxDataRate      921600 bps
        bNumDataRatesSupp.      0
        dwMaxIFSD               0
        dwSyncProtocols  00000000 
        dwMechanical     00000000 
        dwFeatures       000100B0
          Auto clock change
          Auto baud rate change
          Auto PPS made by CCID
          TPDU level exchange
        dwMaxCCIDMsgLen       272
        bClassGetResponse    echo
        bClassEnvelope       echo
        wlcdLayout           none
        bPINSupport             0 
        bMaxCCIDBusySlots       8
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x02  EP 2 OUT
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0040  1x 64 bytes
        bInterval               0
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x83  EP 3 IN
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0040  1x 64 bytes
        bInterval               0
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x84  EP 4 IN
        bmAttributes            3
          Transfer Type            Interrupt
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0040  1x 64 bytes
        bInterval              16
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        1
      bAlternateSetting       0
      bNumEndpoints           0
      bInterfaceClass       254 Application Specific Interface
      bInterfaceSubClass      1 Device Firmware Update
      bInterfaceProtocol      1 
      iInterface              8 sysmoOCTSIM DFU (Runtime)
      Device Firmware Upgrade Interface Descriptor:
        bLength                             9
        bDescriptorType                    33
        bmAttributes                        8
          Will Detach
          Manifestation Intolerant
          Upload Unsupported
          Download Unsupported
        wDetachTimeout                      0 milliseconds
        wTransferSize                     512 bytes
        bcdDFUVersion                   1.00
Device Status:     0x0000
  (Bus Powered)
---
Diff with expected output:
---
Test 03_check_lsusb.sh passed
==> Executing Testcase 04_check_dfu_lsusb.sh
resetting target to dfu
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
BITFT_1=0
BITFT_2=1
BITFT_1=1
BITFT_2=1
done

ID 1d50:6141 OpenMoko, Inc. sysmoOCTSIM DFU-0.2.2-1644
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               2.00
  bDeviceClass            0 
  bDeviceSubClass         0 
  bDeviceProtocol         0 
  bMaxPacketSize0        64
  idVendor           0x1d50 OpenMoko, Inc.
  idProduct          0x6141 
  bcdDevice            0.00
  iManufacturer           1 sysmocom - s.f.m.c. GmbH
  iProduct                2 sysmoOCTSIM DFU-0.2.2-1644
  iSerial                 3 ecc68ade3335355320202034463715ff
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                 9
    bDescriptorType         2
    wTotalLength       0x001b
    bNumInterfaces          1
    bConfigurationValue     1
    iConfiguration          0 
    bmAttributes         0x80
      (Bus Powered)
    MaxPower              100mA
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        0
      bAlternateSetting       0
      bNumEndpoints           0
      bInterfaceClass       254 Application Specific Interface
      bInterfaceSubClass      1 Device Firmware Update
      bInterfaceProtocol      2 
      iInterface              4 SAM D5x/E5x DFU bootloader (DFU mode)
      Device Firmware Upgrade Interface Descriptor:
        bLength                             9
        bDescriptorType                    33
        bmAttributes                        9
          Will Detach
          Manifestation Intolerant
          Upload Unsupported
          Download Supported
        wDetachTimeout                      0 milliseconds
        wTransferSize                     512 bytes
        bcdDFUVersion                   1.10
Device Status:     0x0000
  (Bus Powered)
resetting target
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
done
---
Diff with expected output:
---
Test 04_check_dfu_lsusb.sh passed
==> Executing Testcase 05_flash_dfu_from_app.sh
installed fw version: 0.3.49-be7b
resetting target
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
done
dfu-util 0.11

Copyright 2005-2009 Weston Schmidt, Harald Welte and OpenMoko Inc.
Copyright 2010-2021 Tormod Volden and Stefan Schmidt
This program is Free Software and has ABSOLUTELY NO WARRANTY
Please report bugs to http://sourceforge.net/p/dfu-util/tickets/

Opening DFU capable USB device...
Device ID 1d50:6141
Run-Time device DFU version 0100
Claiming USB DFU (Run-Time) Interface...
Setting Alternate Interface zero...
Determining device status...
DFU state(0) = appIDLE, status(0) = No error condition is present
Device really in Run-Time Mode, send DFU detach request...
Device will detach and reattach...
Opening DFU USB Device...
Claiming USB DFU Interface...
Setting Alternate Interface #0 ...
Determining device status...
DFU state(2) = dfuIDLE, status(0) = No error condition is present
DFU mode device DFU version 0110
Device returned transfer size 512
Copying data from PC to DFU device
Download done.
installed fw version: 0.3.49-be7b
---
Diff with expected output:
---
Test 05_flash_dfu_from_app.sh passed
==> Executing Testcase 06_test_simcards.sh
resetting target
BITFT_1=1
BITFT_2=0
BITFT_1=0
BITFT_2=0
done
installed fw version: 0.3.49-be7b
card slot 0 - pysimread
Terminated
Build was aborted
Aborted by Oliver Smith
Terminated
---
Diff with expected output:
Terminated
--- 06_test_simcards.out	2026-04-14 11:14:03.034031807 +0200
+++ /tmp/fileedLITe	2026-04-14 11:14:59.298692160 +0200
@@ -5,5205 +5,3 @@
 BITFT_2=0
 done
 card slot 0 - pysimread
-Using reader PCSC[sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (ecc68ade3335355320202034463715ff) 00 00]
-Reading ...
-Autodetected card type: sysmoUSIM-SJS1
-ICCID: 8988211000000090160
-IMSI: 001640000069444
-GID1: ffffffffffffffffffff
-GID2: ffffffffffffffffffff
-SMSP: ffffffffffffffffffffffffffffffffffffffffffffffffe1ffffffffffffffffffffffff0581005155f5ffffffffffff000000
-SPN: Not available
-Show in HPLMN: False
-Hide in OPLMN: False
-PLMNsel: ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff
-PLMNwAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-OPLMNwAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-HPLMNAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-ACC: 0040
-MSISDN: Can't read file -- Length of MSISDN (136 bytes) is out of range
-Administrative data: 00000002
-	MS operation mode: normal
-	Ciphering Indicator: disabled
-SIM Service Table: ff3fffff3f003f1ff00c00c0f00000
-	Service 1 - CHV1 disable function
-	Service 2 - Abbreviated Dialling Numbers (ADN)
-	Service 3 - Fixed Dialling Numbers (FDN)
-	Service 4 - Short Message Storage (SMS)
-	Service 5 - Advice of Charge (AoC)
-	Service 6 - Capability Configuration Parameters (CCP)
-	Service 7 - PLMN selector
-	Service 8 - RFU
-	Service 9 - MSISDN
-	Service 10 - Extension1
-	Service 11 - Extension2
-	Service 12 - SMS Parameters
-	Service 13 - Last Number Dialled (LND)
-	Service 14 - Cell Broadcast Message Identifier
-	Service 17 - Service Provider Name
-	Service 18 - Service Dialling Numbers (SDN)
-	Service 19 - Extension3
-	Service 20 - RFU
-	Service 21 - VGCS Group Identifier List (EFVGCS and EFVGCSS)
-	Service 22 - VBS Group Identifier List (EFVBS and EFVBSS)
-	Service 23 - enhanced Multi-Level Precedence and Pre-emption Service
-	Service 24 - Automatic Answer for eMLPP
-	Service 25 - Data download via SMS-CB
-	Service 26 - Data download via SMS-PP
-	Service 27 - Menu selection
-	Service 28 - Call control
-	Service 29 - Proactive SIM
-	Service 30 - Cell Broadcast Message Identifier Ranges
-	Service 31 - Barred Dialling Numbers (BDN)
-	Service 32 - Extension4
-	Service 33 - De-personalization Control Keys
-	Service 34 - Co-operative Network List
-	Service 35 - Short Message Status Reports
-	Service 36 - Network's indication of alerting in the MS
-	Service 37 - Mobile Originated Short Message control by SIM
-	Service 38 - GPRS
-	Service 49 - MExE
-	Service 50 - Reserved and shall be ignored
-	Service 51 - PLMN Network Name
-	Service 52 - Operator PLMN List
-	Service 53 - Mailbox Dialling Numbers
-	Service 54 - Message Waiting Indication Status
-	Service 57 - Multimedia Messaging Service (MMS)
-	Service 58 - Extension 8
-	Service 59 - MMS User Connectivity Parameters
-
-FPLMN:
-	62f230 # MCC: 262 MNC: 03
-	62f270 # MCC: 262 MNC: 07
-	62f210 # MCC: 262 MNC: 01
-	62f220 # MCC: 262 MNC: 02
-
-USIM Service Table: 9e6b1dfc67f6580000
-	Service 2 - Fixed Dialling Numbers (FDN)
-	Service 3 - Extension 2
-	Service 4 - Service Dialling Numbers (SDN)
-	Service 5 - Extension3
-	Service 8 - Outgoing Call Information (OCI and OCT)
-	Service 9 - Incoming Call Information (ICI and ICT)
-	Service 10 - Short Message Storage (SMS)
-	Service 12 - Short Message Service Parameters (SMSP)
-	Service 14 - Capability Configuration Parameters 2 (CCP2)
-	Service 15 - Cell Broadcast Message Identifier
-	Service 17 - Group Identifier Level 1
-	Service 19 - Service Provider Name
-	Service 20 - User controlled PLMN selector with Access Technology
-	Service 21 - MSISDN
-	Service 27 - GSM Access
-	Service 28 - Data download via SMS-PP
-	Service 29 - Data download via SMS-CB
-	Service 30 - Call Control by USIM
-	Service 31 - MO-SMS Control by USIM
-	Service 32 - RUN AT COMMAND command
-	Service 33 - shall be set to 1
-	Service 34 - Enabled Services Table
-	Service 35 - APN Control List (ACL)
-	Service 38 - GSM security context
-	Service 39 - CPBCCH Information
-	Service 42 - Operator controlled PLMN selector with Access Technology
-	Service 43 - HPLMN selector with Access Technology
-	Service 45 - PLMN Network Name
-	Service 46 - Operator PLMN List
-	Service 47 - Mailbox Dialling Numbers
-	Service 48 - Message Waiting Indication Status
-	Service 52 - Multimedia Messaging Service (MMS)
-	Service 53 - Extension 8
-	Service 55 - MMS User Connectivity Parameters
-
-Done !
-
-
-card slot 4 - pysimread
-Using reader PCSC[sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (ecc68ade3335355320202034463715ff) 00 04]
-Reading ...
-Autodetected card type: sysmoUSIM-SJS1
-ICCID: 8988211000000271083
-IMSI: 001640000069555
-GID1: ffffffffffffffffffff
-GID2: ffffffffffffffffffff
-SMSP: ffffffffffffffffffffffffffffffffffffffffffffffffe1ffffffffffffffffffffffff0581005155f5ffffffffffff000000
-SPN: Not available
-Show in HPLMN: False
-Hide in OPLMN: False
-PLMNsel: ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff
-PLMNwAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-OPLMNwAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-HPLMNAcT:
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-	ffffffffff # unused
-
-ACC: 0100
-MSISDN: Not available
-Administrative data: 00000002
-	MS operation mode: normal
-	Ciphering Indicator: disabled
-SIM Service Table: ff3fffff3f003f1ff00c00c0f00000
-	Service 1 - CHV1 disable function
-	Service 2 - Abbreviated Dialling Numbers (ADN)
-	Service 3 - Fixed Dialling Numbers (FDN)
-	Service 4 - Short Message Storage (SMS)
-	Service 5 - Advice of Charge (AoC)
-	Service 6 - Capability Configuration Parameters (CCP)
-	Service 7 - PLMN selector
-	Service 8 - RFU
-	Service 9 - MSISDN
-	Service 10 - Extension1
-	Service 11 - Extension2
-	Service 12 - SMS Parameters
-	Service 13 - Last Number Dialled (LND)
-	Service 14 - Cell Broadcast Message Identifier
-	Service 17 - Service Provider Name
-	Service 18 - Service Dialling Numbers (SDN)
-	Service 19 - Extension3
-	Service 20 - RFU
-	Service 21 - VGCS Group Identifier List (EFVGCS and EFVGCSS)
-	Service 22 - VBS Group Identifier List (EFVBS and EFVBSS)
-	Service 23 - enhanced Multi-Level Precedence and Pre-emption Service
-	Service 24 - Automatic Answer for eMLPP
-	Service 25 - Data download via SMS-CB
-	Service 26 - Data download via SMS-PP
-	Service 27 - Menu selection
-	Service 28 - Call control
-	Service 29 - Proactive SIM
-	Service 30 - Cell Broadcast Message Identifier Ranges
-	Service 31 - Barred Dialling Numbers (BDN)
-	Service 32 - Extension4
-	Service 33 - De-personalization Control Keys
-	Service 34 - Co-operative Network List
-	Service 35 - Short Message Status Reports
-	Service 36 - Network's indication of alerting in the MS
-	Service 37 - Mobile Originated Short Message control by SIM
-	Service 38 - GPRS
-	Service 49 - MExE
-	Service 50 - Reserved and shall be ignored
-	Service 51 - PLMN Network Name
-	Service 52 - Operator PLMN List
-	Service 53 - Mailbox Dialling Numbers
-	Service 54 - Message Waiting Indication Status
-	Service 57 - Multimedia Messaging Service (MMS)
-	Service 58 - Extension 8
-	Service 59 - MMS User Connectivity Parameters
-
-FPLMN:
-	62f210 # MCC: 262 MNC: 01
-	62f220 # MCC: 262 MNC: 02
-	62f230 # MCC: 262 MNC: 03
-	62f270 # MCC: 262 MNC: 07
-
-USIM Service Table: 9e6b1dfc67f6580000
-	Service 2 - Fixed Dialling Numbers (FDN)
-	Service 3 - Extension 2
-	Service 4 - Service Dialling Numbers (SDN)
-	Service 5 - Extension3
-	Service 8 - Outgoing Call Information (OCI and OCT)
-	Service 9 - Incoming Call Information (ICI and ICT)
-	Service 10 - Short Message Storage (SMS)
-	Service 12 - Short Message Service Parameters (SMSP)
-	Service 14 - Capability Configuration Parameters 2 (CCP2)
-	Service 15 - Cell Broadcast Message Identifier
-	Service 17 - Group Identifier Level 1
-	Service 19 - Service Provider Name
-	Service 20 - User controlled PLMN selector with Access Technology
-	Service 21 - MSISDN
-	Service 27 - GSM Access
-	Service 28 - Data download via SMS-PP
-	Service 29 - Data download via SMS-CB
-	Service 30 - Call Control by USIM
-	Service 31 - MO-SMS Control by USIM
-	Service 32 - RUN AT COMMAND command
-	Service 33 - shall be set to 1
-	Service 34 - Enabled Services Table
-	Service 35 - APN Control List (ACL)
-	Service 38 - GSM security context
-	Service 39 - CPBCCH Information
-	Service 42 - Operator controlled PLMN selector with Access Technology
-	Service 43 - HPLMN selector with Access Technology
-	Service 45 - PLMN Network Name
-	Service 46 - Operator PLMN List
-	Service 47 - Mailbox Dialling Numbers
-	Service 48 - Message Waiting Indication Status
-	Service 52 - Multimedia Messaging Service (MMS)
-	Service 53 - Extension 8
-	Service 55 - MMS User Connectivity Parameters
-
-Done !
-
-
-card slot 0 - pysimshell
-Using reader PCSC[sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (ecc68ade3335355320202034463715ff) 00 00]
-Waiting for card...
-Info: Card is of type: UICC
-Detected UICC Add-on "SIM"
-AIDs on card:
- USIM: a0000000871002ffffffff8907090000 (EF.DIR)
- ADF.ISD: a000000003000000
-################################################################################
-# MF                                                                           #
-################################################################################
-# directory: MF (3f00)
-# file: MF (3f00)
-# RAW FCP Template: 62548202782183023f00a51980017183027fffcb0d00000000000000000000000000ca01828a0105ab1b84012e9000840188a4068301019501088401fca40683010a950108c60f90017083010183010a83010b830181
-# Decoded FCP Template: {'file_descriptor': {'file_descriptor_byte': {'shareable': True, 'file_type': 'df', 'structure': 'no_info_given'}, 'record_len': None, 'num_of_rec': None}, 'file_identifier': '3f00', 'proprietary_information': {'uicc_characteristics': b'q', 'available_memory': 32767, 'unknown_ber_tlv_ie_cb': {'raw': '00000000000000000000000000'}, 'unknown_ber_tlv_ie_ca': {'raw': '82'}}, 'life_cycle_status_integer': 'operational_activated', 'security_attrib_expanded': b'\x84\x01.\x90\x00\x84\x01\x88\xa4\x06\x83\x01\x01\x95\x01\x08\x84\x01\xfc\xa4\x06\x83\x01\n\x95\x01\x08', 'pin_status_template_do': [{'ps_do': b'p'}, {'key_reference': 1}, {'key_reference': 10}, {'key_reference': 11}, {'key_reference': 129}]}
-select MF
-# MF(3f00) has no exportable contents
-#
-################################################################################
-# MF/DF.GSM                                                                    #
-################################################################################
-# directory: MF/DF.GSM (3f00/7f20)
-# file: DF.GSM (7f20)
-# RAW FCP Template: 62308202782183027f20a51683027fffcb0d00000000000000000000000000ca01828a01058b032f0601c606900100830101
-# Decoded FCP Template: {'file_descriptor': {'file_descriptor_byte': {'shareable': True, 'file_type': 'df', 'structure': 'no_info_given'}, 'record_len': None, 'num_of_rec': None}, 'file_identifier': '7f20', 'proprietary_information': {'available_memory': 32767, 'unknown_ber_tlv_ie_cb': {'raw': '00000000000000000000000000'}, 'unknown_ber_tlv_ie_ca': {'raw': '82'}}, 'life_cycle_status_integer': 'operational_activated', 'security_attrib_referenced': {'ef_arr_file_id': '2f06', 'ef_arr_record_nr': 1}, 'pin_status_template_do': {'ps_do': b'\x00', 'key_reference': 1}}
-select MF/DF.GSM
-# DF(DF.GSM) has no exportable contents
-#
-################################################################################
-# MF/DF.GSM/EF.LP                                                              #
-################################################################################
-# directory: MF/DF.GSM/EF.LP (3f00/7f20/6f05)
-# file: EF.LP (6f05)
-# structure: transparent
-# RAW FCP Template: 621e8202412183026f05a506c00100ca01808a01058b036f0602800200058800
-# Decoded FCP Template: {'file_descriptor': {'file_descriptor_byte': {'shareable': True, 'file_type': 'working_ef', 'structure': 'transparent'}, 'record_len': None, 'num_of_rec': None}, 'file_identifier': '6f05', 'proprietary_information': {'special_file_info': {'high_update_activity': False, 'readable_and_updatable_when_deactivated': False}, 'unknown_ber_tlv_ie_ca': {'raw': '80'}}, 'life_cycle_status_integer': 'operational_activated', 'security_attrib_referenced': {'ef_arr_file_id': '6f06', 'ef_arr_record_nr': 2}, 'file_size': 5, 'short_file_identifier': None}
-select MF/DF.GSM/EF.LP
-update_binary ffffffffff
-#
-################################################################################
-# MF/DF.GSM/EF.IMSI                                                            #
-################################################################################
-# directory: MF/DF.GSM/EF.IMSI (3f00/7f20/6f07)
-# file: EF.IMSI (6f07)
-# structure: transparent
-# RAW FCP Template: 62228202412183026f07a50ac00100cd02ff01ca01848a01058b036f0603800200098800
-# Decoded FCP Template: {'file_descriptor': {'file_descriptor_byte': {'shareable': True, 'file_type': 'working_ef', 'structure': 'transparent'}, 'record_len': None, 'num_of_rec': None}, 'file_identifier': '6f07', 'proprietary_information': {'special_file_info': {'high_update_activity': False, 'readable_and_updatable_when_deactivated': False}, 'unknown_ber_tlv_ie_cd': {'raw': 'ff01'}, 'unknown_ber_tlv_ie_ca': {'raw': '84'}}, 'life_cycle_status_integer': 'operational_activated', 'security_attrib_referenced': {'ef_arr_file_id': '6f06', 'ef_arr_record_nr': 3}, 'file_size': 9, 'short_file_identifier': None}
-select MF/DF.GSM/EF.IMSI
-update_binary 080910460000604944
-#
-################################################################################
-# MF/DF.GSM/EF.Kc                                                              #
-################################################################################
-# directory: MF/DF.GSM/EF.Kc (3f00/7f20/6f20)
-# file: EF.Kc (6f20)
-# structure: transparent
-# RAW FCP Template: 62228202412183026f20a50ac00100cd02ff01ca01848a01058b036f0604800200098800
-# Decoded FCP Template: {'file_descriptor': {'file_descriptor_byte': {'shareable': True, 'file_type': 'working_ef', 'structure': 'transparent'}, 'record_len': None, 'num_of_rec': None}, 'file_identifier': '6f20', 'proprietary_information': {'special_file_info': {'high_update_activity': False, 'readable_and_updatable_when_deactivated': False}, 'unknown_ber_tlv_ie_cd': {'raw': 'ff01'}, 'unknown_ber_tlv_ie_ca': {'raw': '84'}}, 'life_cycle_status_integer': 'operational_activated', 'security_attrib_referenced': {'ef_arr_file_id': '6f06', 'ef_arr_record_nr': 4}, 'file_size': 9, 'short_file_identifier': None}
-select MF/DF.GSM/EF.Kc
-update_binary 9159f4eb3d94922a07
-#
-################################################################################
-# MF/DF.GSM/EF.PLMNsel                                                         #
-################################################################################
-# directory: MF/DF.GSM/EF.PLMNsel (3f00/7f20/6f30)
-# file: EF.PLMNsel (6fFinished: ABORTED