server: vty: validate rotate-localtime modulus against the new interval

apply_rotate_localtime() computed the maximum allowed modulus from
pcap_server->rotate_localtime.intv, the currently-stored (old) interval,
rather than the intv argument being applied.  On first configuration the
stored interval is the default 0, so the switch hit the default case and
rejected an otherwise valid command; when changing intervals the modulus
was bounds-checked against the wrong interval.  Switch on intv instead.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Change-Id: I0b367d4e255db3208b41e12adec682026b99cc18