Skip to content

Failed

handover_2G:trx-sysmocell5000+bts1-sysmo.handover.py (from handover_2G_trx-sysmocell5000+bts1-sysmo)

Failing for the past 25 builds (Since #140 )
Took 5 min 54 sec.

Stacktrace

handover.py: Wait timeout {condition=<bound method OsmoBsc.bts_is_connected of osmo-bsc_10.42.42.7>, timeout=300, timestep=1} [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:43]

Standard Output

----------------------------------------------
trial-164 handover_2G:trx-sysmocell5000+bts1-sysmo handover.py
----------------------------------------------
16:03:24.757135 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:24.772145 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x bts (candidates: 2)
16:03:24.930321 tst                      handover.py: using LAC 16438
16:03:25.069667 tst                      handover.py: using RAC 118
16:03:25.203137 tst                      handover.py: using CellId 16437
16:03:25.337400 tst                      handover.py: using BVCI 3116
16:03:25.363824 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x bts (candidates: 2)
16:03:25.503780 tst                      handover.py: using LAC 16439
16:03:25.636540 tst                      handover.py: using RAC 119
16:03:25.769028 tst                      handover.py: using CellId 16438
16:03:25.902019 tst                      handover.py: using BVCI 3117
16:03:25.928477 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:25.942123 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:25.955622 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:25.969314 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:25.982764 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x ip_address (candidates: 6)
16:03:25.996133 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x modem (candidates: 2)
16:03:26.130232 tst handover_2G:trx-sysmocell5000+bts1-sysmo: Using 1 x modem (candidates: 2)
16:03:26.376760 run              osmo-hlr_10.42.42.2: Starting osmo-hlr
16:03:26.896105 run         create_hlr_db(pid=13277): Launched
16:03:27.040254 bus                        /sierra_2: Setting Powered False
16:03:28.125487 run         create_hlr_db(pid=13277): Terminated: ok {rc=0}
16:03:28.587164 run pcap-recorder_any(filters='host 10.42.42.2')(pid=13279): Launched
16:03:28.939684 run   osmo-hlr_10.42.42.2(pid=13280): Launched
16:03:29.063974 run              osmo-stp_10.42.42.5: Starting osmo-stp
16:03:29.642121 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=13281): Launched
16:03:29.992987 run   osmo-stp_10.42.42.5(pid=13282): Launched
16:03:30.117311 run              osmo-msc_10.42.42.6: Starting osmo-msc
16:03:30.730212 run pcap-recorder_any(filters='host 10.42.42.6 and port not 22')(pid=13283): Launched
16:03:31.092143 run   osmo-msc_10.42.42.6(pid=13284): Launched
16:03:31.235311 run              osmo-mgw_10.42.42.3: Starting osmo-mgw
16:03:31.863976 run pcap-recorder_any(filters='host 10.42.42.3 and port not 22')(pid=13285): Launched
16:03:32.226101 run   osmo-mgw_10.42.42.3(pid=13286): Launched
16:03:32.361100 run              osmo-mgw_10.42.42.4: Starting osmo-mgw
16:03:32.958976 run pcap-recorder_any(filters='host 10.42.42.4 and port not 22')(pid=13287): Launched
16:03:33.309894 run   osmo-mgw_10.42.42.4(pid=13288): Launched
16:03:33.434637 run              osmo-bsc_10.42.42.7: Starting osmo-bsc
16:03:34.219591 run pcap-recorder_any(filters='host 10.42.42.7 and port not 22')(pid=13289): Launched
16:03:34.589180 run   osmo-bsc_10.42.42.7(pid=13290): Launched
16:03:38.305292 run                     osmo-bts-trx: Starting to connect to osmo-bsc_10.42.42.7
16:03:40.653526 run          ssh_sc5_ccli(pid=13291): Launched
16:03:59.909964 run          ssh_sc5_ccli(pid=13291): ERR: Terminated: ERROR {rc=255}  [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:42↪handover.py↪osmo-bts-trx↪sc5-trx↪ssh_sc5_ccli(pid=13291)]
16:04:00.073129 run          ssh_sc5_ccli(pid=13291): stdout: 
| (launched: 2020-12-07_16:03:40.464731) 
16:04:00.237330 run          ssh_sc5_ccli(pid=13291): stderr: 
| (launched: 2020-12-07_16:03:40.519964)
| ssh: connect to host 10.42.42.112 port 22: No route to host 
16:04:00.378613 run                          sc5-trx: Configuring SC5 TRX failed, retrying 9 more times
16:04:05.762662 run          ssh_sc5_ccli(pid=13293): Launched
16:04:08.981420 run          ssh_sc5_ccli(pid=13293): ERR: Terminated: ERROR {rc=255}  [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:42↪handover.py↪osmo-bts-trx↪sc5-trx↪ssh_sc5_ccli(pid=13293)]
16:04:09.134647 run          ssh_sc5_ccli(pid=13293): stdout: 
| (launched: 2020-12-07_16:04:05.579617) 
16:04:09.288958 run          ssh_sc5_ccli(pid=13293): stderr: 
| (launched: 2020-12-07_16:04:05.638214)
| ssh: connect to host 10.42.42.112 port 22: No route to host 
16:04:09.420768 run                          sc5-trx: Configuring SC5 TRX failed, retrying 8 more times
16:04:14.799454 run          ssh_sc5_ccli(pid=13294): Launched
16:04:16.028467 run          ssh_sc5_ccli(pid=13294): Terminated: ok {rc=0}
16:04:16.166942 run                     osmo-bts-trx: Waiting for sc5-trx to start up...
16:04:17.503440 run          osmo-bts-trx(pid=13295): Launched
16:09:18.294476 tst                   handover.py:43: ----- Report fragment: handover_2G:trx-sysmocell5000+bts1-sysmo/handover.py/01_bts0_started: FAIL (340.1s)
16:09:18.302552 tst                   handover.py:43: ERR: Error: handover.py: Wait timeout {condition=&lt;bound method OsmoBsc.bts_is_connected of osmo-bsc_10.42.42.7&gt;, timeout=300, timestep=1} [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:43]  [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:43]
16:09:18.310448 tst                   handover.py:43: Test FAILED (353.5 sec)
16:09:18.356716 run pcap-recorder_any(filters='host 10.42.42.2')(pid=13279): Terminating (SIGTERM)
16:09:18.409183 run   osmo-hlr_10.42.42.2(pid=13280): Terminating (SIGTERM)
16:09:18.462993 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=13281): Terminating (SIGTERM)
16:09:18.519078 run   osmo-stp_10.42.42.5(pid=13282): Terminating (SIGTERM)
16:09:18.573452 run pcap-recorder_any(filters='host 10.42.42.6 and port not 22')(pid=13283): Terminating (SIGTERM)
16:09:18.627514 run   osmo-msc_10.42.42.6(pid=13284): Terminating (SIGTERM)
16:09:18.679848 run pcap-recorder_any(filters='host 10.42.42.3 and port not 22')(pid=13285): Terminating (SIGTERM)
16:09:18.732213 run   osmo-mgw_10.42.42.3(pid=13286): Terminating (SIGTERM)
16:09:18.784015 run pcap-recorder_any(filters='host 10.42.42.4 and port not 22')(pid=13287): Terminating (SIGTERM)
16:09:18.836307 run   osmo-mgw_10.42.42.4(pid=13288): Terminating (SIGTERM)
16:09:18.888662 run pcap-recorder_any(filters='host 10.42.42.7 and port not 22')(pid=13289): Terminating (SIGTERM)
16:09:18.940604 run   osmo-bsc_10.42.42.7(pid=13290): Terminating (SIGTERM)
16:09:18.992741 run          osmo-bts-trx(pid=13295): Terminating (SIGTERM)
16:09:19.004610 ---      ParallelTerminationStrategy: PID 13279 died...
16:09:19.073491 run pcap-recorder_any(filters='host 10.42.42.2')(pid=13279): Terminated: ok {rc=0}
16:09:19.085935 ---      ParallelTerminationStrategy: PID 13280 died...
16:09:19.154639 run   osmo-hlr_10.42.42.2(pid=13280): Terminated: ok {rc=0}
16:09:19.166835 ---      ParallelTerminationStrategy: PID 13281 died...
16:09:19.235126 run pcap-recorder_any(filters='host 10.42.42.5 and port not 22')(pid=13281): Terminated: ok {rc=0}
16:09:19.247375 ---      ParallelTerminationStrategy: PID 13282 died...
16:09:19.315404 run   osmo-stp_10.42.42.5(pid=13282): Terminated: ok {rc=0}
16:09:19.327599 ---      ParallelTerminationStrategy: PID 13283 died...
16:09:19.395855 run pcap-recorder_any(filters='host 10.42.42.6 and port not 22')(pid=13283): Terminated: ok {rc=0}
16:09:19.408118 ---      ParallelTerminationStrategy: PID 13285 died...
16:09:19.476647 run pcap-recorder_any(filters='host 10.42.42.3 and port not 22')(pid=13285): Terminated: ok {rc=0}
16:09:19.488977 ---      ParallelTerminationStrategy: PID 13286 died...
16:09:19.556997 run   osmo-mgw_10.42.42.3(pid=13286): Terminated {rc=15}
16:09:19.569302 ---      ParallelTerminationStrategy: PID 13287 died...
16:09:19.637593 run pcap-recorder_any(filters='host 10.42.42.4 and port not 22')(pid=13287): Terminated: ok {rc=0}
16:09:19.649928 ---      ParallelTerminationStrategy: PID 13288 died...
16:09:19.718202 run   osmo-mgw_10.42.42.4(pid=13288): Terminated {rc=15}
16:09:19.730448 ---      ParallelTerminationStrategy: PID 13289 died...
16:09:19.798756 run pcap-recorder_any(filters='host 10.42.42.7 and port not 22')(pid=13289): Terminated: ok {rc=0}
16:09:21.827813 ---      ParallelTerminationStrategy: PID 13284 died...
16:09:21.897889 run   osmo-msc_10.42.42.6(pid=13284): Terminated: ok {rc=0}
16:09:22.577217 ---      ParallelTerminationStrategy: PID 13290 died...
16:09:22.647374 run   osmo-bsc_10.42.42.7(pid=13290): Terminated: ok {rc=0}
16:09:22.659608 ---      ParallelTerminationStrategy: PID 13295 died...
16:09:22.727662 run          osmo-bts-trx(pid=13295): Terminated: ok {rc=0}
16:09:22.833302 bus                        /sierra_3: Setting Powered False
16:09:23.959938 bus                        /sierra_3: Setting Powered False
16:09:25.092939 bus                        /sierra_2: Setting Powered False

Standard Error

Traceback (most recent call last):
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod_handover/osmo-gsm-tester/src/osmo_gsm_tester/core/test.py", line 76, in run
    self.path)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod_handover/osmo-gsm-tester/src/osmo_gsm_tester/core/util.py", line 414, in run_python_file
    spec.loader.exec_module( importlib.util.module_from_spec(spec) )
  File "<frozen importlib._bootstrap_external>", line 673, in exec_module
  File "<frozen importlib._bootstrap>", line 222, in _call_with_frames_removed
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod_handover/osmo-gsm-tester/sysmocom/suites/handover_2G/handover.py", line 43, in <module>
    wait(bsc.bts_is_connected, bts0)
  File "/home/jenkins/workspace/osmo-gsm-tester_run-prod_handover/osmo-gsm-tester/src/osmo_gsm_tester/core/event_loop.py", line 109, in wait
    raise log.Error('Wait timeout', condition=condition, timeout=timeout, timestep=timestep)
osmo_gsm_tester.core.log.Error: handover.py: Wait timeout {condition=<bound method OsmoBsc.bts_is_connected of osmo-bsc_10.42.42.7>, timeout=300, timestep=1} [trial-164↪handover_2G:trx-sysmocell5000+bts1-sysmo↪handover.py:43]